• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm HK
        • 143494611124M1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm HK

        Article no.: 143494611124M1
        2,943.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • Downloads

        Basic unit

        Kampmann Katherm HK trench heater, ready-to-install floor trench, either for installation in raised or screeded floors, convector-based for heating and cooling with tangential fan convection. Heat and cooling outputs tested in accordance with E DIN EN 16430, parts 1 to 3. Hygiene-certified in line with VDI 6022.
        Trench chassis made of sendzimir galvanised sheet steel, graphite-grey coated. Modular trench unit, consisting of connection, power and extension module. The connection module contains all the building services interfaces consisting of an electrical connection and control box, EC fan motor, water-side heat exchanger connection and the condensate connection on the waste water side, optimized for simple, time-saving installation. Power module consisting of heat exchanger and tangential fan with continuous cascaded tangential rollers. Extension module for the 4-pipe heat exchanger connection.
        With lateral installation aids and step-stable height adjustment, each with impact sound insulation, for secure elevation of the trunking. With pre-punched feed-throughs for water supply and return and electrical connection, on the room side. Trench chassis prepared for condensate pump mounting kit. Segment plates as simultaneous finger protection for the tangential fan and filter fleece support frame, air guide plate, grate support and cross brace for stiffening the duct. Center wall as air guide and mounting plate for the tangential fan.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.9,57E+01. Further calculations possible online.

        Heat exchanger

        High-output heat exchanger, made of round copper pipes with aluminium fins and 1/2-inch valve connection, painted graphite-grey. With sturdy anti-torsion mechanism and simultaneous spray protection when venting. Collector with integral bleed option.
        System4-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C95
        Min. entering water temperature°C5
        Max. air inlet temp.°C40
        Max. glycol volume%50

        Condensate tray

        Condensate tray has a flow-optimised design, for the simultaneous discharge of condensate and air guidance below the convector. Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022.

        Fan

        Tangential fan with safety guard. High-performance energy-saving EC fan with 0-10 V input for continuously variable speed control, sound-optimised. Integrated controller with variable cable design. Valve controlled via 24 VDC control contacts. All rotating parts have low-noise and maintenance-free bearings. Motor monitoring by integrated active temperature management. With ball bearing with long-lasting greasing.
        Even flow through the convector, low power consumption for effective, energy-saving consumption, also sound-optimised for low sound values. Easily removable for cleaning and maintenance due to combined coupling/ball joint system with simultaneous acoustic decoupling. Factory-wired ready for connection. Valve control via 24 VDC control contacts.

        Control

        • Built-in KaControl MC controller for continuous fan control with motor monitoring.
        • For the control of 24 V DC actuators (Open/Closed) for heating and cooling operation.
        • With connection option for 5 multifunctional inputs (room temperature, window contact, supply and return temperature, heating/cooling changeover, condensate alarm, sequential control via a 0-10 V signal etc.), unit-specific control and regulation algorithms with the core functions of room temperature control (heating/cooling).
        • Timer program with battery-backed real-time clock for four operating modes (Day/Eco/Extra/Off), commissioning function.
        • Grouping of up to 10 units and a display to create a control zone using CAN-bus, automatic addressing and communication monitoring of all bus subscribers, continuous synchronisation of all statuses and parameters within the group.
        • CAN bus interface and galvanically isolated RS485 interface, each with two terminal blocks for separate connection with daisy chain cabling with a switchable terminal resistor.
        • connection of central functions, such as heating cooling changeover to a freely selectable unit within the group.
        • Ethernet interface with two RJ45 sockets with built-in switching function.
        • KNX-TP interface with socket terminal, all terminals are designed as plugs, wireless communication via Wi-Fi web server for user-friendly operation and for complete password-protected parametrisation.
        • protocols can be unlocked via licences: BACnet/IP, Modbus TCP, Modbus RTU, KNX.

        Grille

        With frame insert profile, colour-coordinated to the grille. With protective installation cover and frame trim. With screwed cover panels for the connection areas. With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

        Configuration

        Grille designRoll-up grille
        Grille finishAluminium, natural anodised
        Connectionopposite end, cooling connection side on left, heating connection side on right
        Lengthmm1480
        Widthmm290
        Heightmm160
        Bar heightmm18
        Bar depthmm5
        Bar spacingmm12
        Free area, approx. %70
        Weightkg29.5

        Multi Connect climate control

        • KaControl MC control system for operation via separate touch panel TP 2"
        • Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
        • Demand-led automatic or optional manual fan control
        • Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
        • Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device

        EC tangential fan

        • with powerful, noise-optimized EC fan motor
        • as a continuous fan belt with flow-optimized cross-flow rollers, cascaded by an innovative coupling system
        • Continuous, even flow through the convectors
        • Stepless speed control via 0-10 V signal, motor monitoring with internal fault processing

        Attachment of cross-flow fan

        • Easy removal of the tangential fan without tools
        • Innovative combined coupling/ball stud system
        • Simultaneous sound decoupling

        Segment plate

        • As simultaneous finger protection for the tangential fan, filter mounting frame, air guide plate, grate support and cross brace for stiffening the duct

        Control terminal box

        • Ready-wired, for quick and safe electrical connection, saves installation time
        • KaControl MC or electromechanical control
        • With integrated cable duct for clean, safe cable routing

        Connection module

        • includes all building services interfaces on one connection side
        • Simple and time-saving installation
        • with connection and control box, EC fan motor; heat exchanger connection and condensate connection with optional condensate pump

        Cover plate

        • as a privacy screen and protection against soiling
        • for connection and extension module
        • secured with screw plugs

        Connection kit for condensation pump

        • Provided or factory-fitted for draining the condensate; direct wiring in the electrical connection box
        • with quiet condensate pump in compact housing, with connection elbow
        • Plug-in power supply and fault alarm

        • IFront view
        • IItop view (without cover panel)
        • IIIcross-section

        • 1window side
        • 2room side

        Length (A)1,480 mm
        finned length (B)905 mm
        Weight29.5 kg

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq9.20E+012.57E+001.13E+009.57E+013.79E+004.59E-012.21E-015.89E-021.07E+007.46E+000.00E+001.29E-014.32E+006.43E-02-5.20E+01
        GWP - fossil
        Climate change - fossil
        kg CO2 eq9.20E+012.55E+004.11E+009.86E+013.77E+004.54E-012.07E-015.18E-021.06E+006.55E+000.00E+001.29E-014.32E+006.43E-02-5.14E+01
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq-5.39E-015.36E-03-2.98E+00-3.52E+005.36E-033.57E-038.93E-03-5.36E-038.93E-039.07E-010.00E+003.12E-048.21E-046.43E-04-2.50E-02
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq7.09E-011.79E-037.14E-037.18E-016.11E-044.54E-043.57E-031.25E-025.36E-038.93E-030.00E+004.82E-051.09E-046.45E-05-3.73E-01
        ODP
        Ozone Depletion
        kg CFC-11 eq6.13E-066.37E-072.14E-076.99E-068.79E-071.95E-081.77E-084.91E-096.37E-084.45E-070.00E+003.21E-083.71E-081.95E-08-3.46E-06
        AP
        Acidification
        mol H+ eq1.23E+008.93E-038.93E-031.25E+001.96E-021.79E-038.50E-043.95E-044.29E-021.96E-020.00E+004.11E-048.89E-045.37E-04-7.54E-01
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq1.00E-011.66E-045.36E-031.06E-011.14E-041.37E-044.27E-051.79E-053.57E-031.79E-030.00E+008.36E-063.12E-051.86E-05-6.25E-02
        EP - marine
        Eutrophication aquatic marine
        kg P eq1.14E-011.79E-033.57E-031.19E-017.14E-035.12E-042.23E-048.75E-051.79E-035.36E-030.00E+009.18E-053.45E-041.86E-04-6.43E-02
        EP - country
        Eutrophication terrestrial
        mol N eq1.28E+002.14E-022.32E-021.32E+006.96E-023.57E-031.79E-035.81E-043.21E-025.36E-020.00E+001.79E-033.57E-031.79E-03-7.46E-01
        POCP
        Photochemical ozone formation
        kg NMVOC3.72E-015.36E-035.36E-033.83E-011.79E-021.79E-034.43E-041.82E-048.93E-031.25E-020.00E+002.55E-048.16E-044.96E-04-2.16E-01
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq1.80E-026.11E-067.45E-061.80E-023.61E-062.79E-061.35E-068.68E-071.79E-031.86E-050.00E+003.07E-078.84E-072.09E-07-1.43E-02
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ1.21E+034.16E+015.93E+011.31E+035.54E+019.75E+004.95E+006.82E-011.42E+011.75E+020.00E+002.09E+001.01E+001.50E+00-6.34E+02
        WDP
        Water use
        m³ depriv.4.35E+011.39E-011.70E-014.38E+019.11E-025.86E-016.43E-023.04E-029.27E-012.34E-010.00E+007.14E-036.96E-026.43E-02-1.11E+01
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq9.01E+012.54E+004.11E+009.67E+013.75E+004.43E-012.05E-016.25E-021.04E+006.50E+000.00E+001.29E-014.32E+006.25E-02-5.00E+01
        PM
        Particulate Matter emissions
        disease inc.6.29E-062.23E-077.00E-086.58E-061.25E-073.07E-085.75E-093.70E-091.27E-079.27E-080.00E+001.13E-086.25E-091.04E-08-3.91E-06
        IR
        Ionizing radiation, human health
        kBq U-235 eq8.67E+002.11E-016.48E-019.52E+002.59E-013.21E-021.48E-011.79E-031.37E-016.14E+000.00E+001.07E-028.93E-037.14E-03-5.48E+00
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe7.63E+033.25E+013.07E+017.69E+033.43E+011.06E+014.07E+001.76E+003.41E+028.14E+010.00E+001.64E+001.61E+011.07E+00-5.51E+03
        HTP - C
        Human toxicity, cancer effects
        CTUh4.80E-078.91E-109.00E-104.82E-076.46E-104.64E-099.07E-119.00E-111.31E-081.65E-090.00E+004.46E-115.05E-104.59E-11-2.93E-07
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh1.17E-053.39E-082.87E-081.18E-054.84E-082.30E-082.55E-092.04E-095.70E-074.70E-080.00E+001.71E-097.14E-097.11E-10-8.61E-06
        SQP
        Land use related impacts/Soil quality
        -5.63E+024.91E+012.20E+028.32E+022.68E+011.24E+002.29E+001.04E+001.69E+016.59E+010.00E+002.48E+003.46E-013.71E+00-3.02E+02

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ2.75E+025.29E-014.62E+013.22E+023.73E-013.39E-011.05E+001.64E-013.09E+003.18E+010.00E+002.68E-029.82E-022.50E-02-1.21E+02
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ2.75E+025.29E-014.62E+013.22E+023.73E-013.39E-011.05E+001.64E-013.09E+003.18E+010.00E+002.68E-029.82E-022.50E-02-1.21E+02
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ1.21E+034.16E+015.93E+011.31E+035.54E+019.75E+004.95E+006.96E-011.42E+011.75E+020.00E+002.09E+001.01E+001.50E+00-6.34E+02
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ1.21E+034.16E+015.93E+011.31E+035.54E+019.75E+004.95E+006.96E-011.42E+011.75E+020.00E+002.09E+001.01E+001.50E+00-6.34E+02
        SM
        Secondary material
        kg6.47E-020.00E+000.00E+006.47E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ4.39E-040.00E+000.00E+004.39E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ2.82E-020.00E+000.00E+002.82E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³8.81E-018.93E-031.96E-029.09E-017.14E-031.07E-023.57E-030.00E+003.21E-024.29E-020.00E+004.29E-043.57E-031.79E-03-3.52E-01

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg3.42E+000.00E+000.00E+003.42E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg2.22E+000.00E+006.30E+008.53E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg2.84E-030.00E+000.00E+002.84E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg1.11E-030.00E+000.00E+001.11E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.91E+010.00E+000.00E+00
        MER
        Materials for energy recovery
        kg4.87E-060.00E+000.00E+004.87E-060.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.51E+000.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00