• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm HK
        • 143242611155C1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm HK

        Article no.: 143242611155C1
        4,195.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • BIM
        • Downloads

        Basic unit

        Kampmann Katherm HK trench heater, ready-to-install floor trench, either for installation in raised or screeded floors, convector-based for heating and cooling with tangential fan convection. Heat and cooling outputs tested in accordance with E DIN EN 16430, parts 1 to 3. Hygiene-certified in line with VDI 6022.
        Floor trench made of sendzimir galvanised sheet steel, painted graphite grey on both sides. Height adjustment feet on the side to adjust the trench height, fitted with impact sound insulation, raised floor height adjustment feet with impact noise insulation, for the secure support of the trench. With pre-punched connection openings for water flow and return pipes and electrical connection, on the room side. Floor trench configured for condensation pump kit. Segment panels act as a finger guard for the tangential fan and as frame for the filter, airflow baffle, grille seat and reinforcing stays to strengthen the trench. Central wall acts as an air guide and support for the tangential fan.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.1,83E+02. Further calculations possible online.

        Heat exchanger

        High-output heat exchanger made of round copper pipes with aluminium fins and Eurokonus valve connection, painted graphite-grey. With anti-twist mechanism. Collector with integral bleed option.
        System2-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C95
        Min. entering water temperature°C5
        Max. air inlet temp.°C40
        Max. glycol volume%50

        Condensate tray

        Condensate tray has a flow-optimised design, for the simultaneous discharge of condensate and air guidance below the convector Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022.

        Fan

        Tangential fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control with sound-optimised commutation electronics. Valve controlled via 24 V DC control contacts. All rotating parts have low-noise and maintenance-free bearings. Motor monitoring with internal fault processing.
        Even flow through the convector, low power consumption for effective, energy-saving consumption, also sound-optimised for low sound values. Easily removable for cleaning and maintenance due to combined coupling/ball joint system with simultaneous acoustic decoupling. With sound-optimised commutation electronics Factory-wired ready for connection. Valve controlled via 24 V DC control contacts.

        Control

        KaControl smart board control version, electrical connection unit factory-fitted and wired in the unit. Operation via a separate room control unit acting as a master unit or used as a slave unit in group mode, alternatively single unit control via an analogue 0-10 V signal, alternatively single unit control via communication cards.
        KaControl control board functions:
        • room control of up to six units via a KaControl t-LAN interface
        • room control of up to 30 units and CANbus card additionally required
        • Temperature measurement optionally via sensor in the room control unit or external room temperature sensor
        • Slot for communication cards (KNX TP, Modbus RTU)
        • two digital inputs, parametrisable
        • condensate alarm
        • Device On/Off
        • Comfort/Economy switch-over with invertible switching logic
        • Three multifunction inputs, e.g. for room temperature or air intake sensors.
        • Two digital outputs for control of 1 heating valve / 1 cooling valve 24 V DC
        • error message 24 V DC, only with 2-pipe
        • optional fan activation via contact sensor opt.
        • room and unit frost protection control
        • offset function for temperature sensor
        • Demand-led or manual fan control (0-100%)
        • parameter-driven integration of natural convection into the control sequence
        • Sequential control of valve and fan via a 0-10 VDC point. Motor monitoring with fault signal processing on the KaControl control board factory-wired ready for connection.

        Grille

        With frame insert profile, colour-coordinated to the grille. With protective installation cover and frame trim. With cover panels for connection areas. With double T-profile grille. Connections made of corrosion-proof steel springs with matching spacers.

        Configuration

        Grille designRoll-up grille
        Grille finishAluminium, natural anodised
        ConnectionEurokonus, same-end, heating/cooling connection side on left
        Lengthmm3000
        Widthmm245
        Heightmm160
        Bar heightmm18
        Bar depthmm5
        Bar spacingmm12
        Free area, approx. %70
        Weightkg56.8

        EC tangential fan

        • with powerful, noise-optimized EC fan motor
        • as a continuous fan belt with flow-optimized cross-flow rollers, cascaded by an innovative coupling system
        • Continuous, even flow through the convectors
        • Stepless speed control via 0-10 V signal, motor monitoring with internal fault processing

        Attachment of cross-flow fan

        • Easy removal of the tangential fan without tools
        • Innovative combined coupling/ball stud system
        • Simultaneous sound decoupling

        Segment plate

        • As simultaneous finger protection for the tangential fan, filter mounting frame, air guide plate, grate support and cross brace for stiffening the duct

        Control terminal box

        • for a quick and safe electrical connection, saves installation time
        • KaControl MC or electromechanical control

        Cover plate

        • as a privacy screen and protection against soiling
        • for connection/deflection and intermediate areas

        Connection kit for condensation pump

        • As accessories, for draining the condensate if necessary
        • provided or factory-fitted
        • Electrical connection on site

        • IFront view
        • IItop view (without cover panel)
        • IIIcross-section

        • 1window side
        • 2room side

        Length (A)3,000 mm
        finned length (B)2,460 mm
        Weight56.7 kg

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq1.76E+024.91E+002.16E+001.83E+027.23E+008.76E-014.23E-011.13E-012.05E+001.43E+010.00E+002.46E-018.25E+001.23E-01-9.92E+01
        GWP - fossil
        Climate change - fossil
        kg CO2 eq1.76E+024.88E+007.84E+001.88E+027.19E+008.66E-013.96E-019.89E-022.02E+001.25E+010.00E+002.46E-018.25E+001.23E-01-9.82E+01
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq-1.03E+001.02E-02-5.69E+00-6.71E+001.02E-026.82E-031.70E-02-1.02E-021.70E-021.73E+000.00E+005.95E-041.57E-031.23E-03-4.77E-02
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq1.35E+003.41E-031.36E-021.37E+001.17E-038.66E-046.82E-032.39E-021.02E-021.70E-020.00E+009.21E-052.07E-041.23E-04-7.13E-01
        ODP
        Ozone Depletion
        kg CFC-11 eq1.17E-051.22E-064.09E-071.33E-051.68E-063.72E-083.38E-089.38E-091.22E-078.49E-070.00E+006.14E-087.09E-083.72E-08-6.62E-06
        AP
        Acidification
        mol H+ eq2.35E+001.70E-021.70E-022.38E+003.75E-023.41E-031.62E-037.54E-048.18E-023.75E-020.00E+007.84E-041.70E-031.03E-03-1.44E+00
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq1.92E-013.17E-041.02E-022.02E-012.18E-042.62E-048.15E-053.41E-056.82E-033.41E-030.00E+001.60E-055.97E-053.55E-05-1.19E-01
        EP - marine
        Eutrophication aquatic marine
        kg P eq2.17E-013.41E-036.82E-032.27E-011.36E-029.79E-044.26E-041.67E-043.41E-031.02E-020.00E+001.75E-046.58E-043.55E-04-1.23E-01
        EP - country
        Eutrophication terrestrial
        mol N eq2.44E+004.09E-024.43E-022.53E+001.33E-016.82E-033.41E-031.11E-036.14E-021.02E-010.00E+003.41E-036.82E-033.41E-03-1.43E+00
        POCP
        Photochemical ozone formation
        kg NMVOC7.11E-011.02E-021.02E-027.32E-013.41E-023.41E-038.46E-043.48E-041.70E-022.39E-020.00E+004.88E-041.56E-039.48E-04-4.13E-01
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq3.43E-021.17E-051.42E-053.43E-026.89E-065.32E-062.58E-061.66E-063.41E-033.55E-050.00E+005.87E-071.69E-063.99E-07-2.73E-02
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ2.31E+037.95E+011.13E+022.50E+031.06E+021.86E+019.45E+001.30E+002.72E+013.33E+020.00E+003.99E+001.93E+002.86E+00-1.21E+03
        WDP
        Water use
        m³ depriv.8.31E+012.66E-013.24E-018.37E+011.74E-011.12E+001.23E-015.80E-021.77E+004.47E-010.00E+001.36E-021.33E-011.23E-01-2.13E+01
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq1.72E+024.84E+007.84E+001.85E+027.16E+008.46E-013.92E-011.19E-011.98E+001.24E+010.00E+002.46E-018.25E+001.19E-01-9.55E+01
        PM
        Particulate Matter emissions
        disease inc.1.20E-054.26E-071.34E-071.26E-052.39E-075.87E-081.10E-087.06E-092.43E-071.77E-070.00E+002.16E-081.19E-081.99E-08-7.47E-06
        IR
        Ionizing radiation, human health
        kBq U-235 eq1.65E+014.02E-011.24E+001.82E+014.94E-016.14E-022.83E-013.41E-032.63E-011.17E+010.00E+002.05E-021.70E-021.36E-02-1.05E+01
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe1.46E+046.21E+015.87E+011.47E+046.55E+012.02E+017.77E+003.36E+006.51E+021.55E+020.00E+003.12E+003.08E+012.04E+00-1.05E+04
        HTP - C
        Human toxicity, cancer effects
        CTUh9.17E-071.70E-091.72E-099.20E-071.23E-098.87E-091.73E-101.72E-102.51E-083.14E-090.00E+008.52E-119.65E-108.76E-11-5.59E-07
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh2.24E-056.48E-085.49E-082.25E-059.24E-084.40E-084.88E-093.89E-091.09E-068.97E-080.00E+003.27E-091.36E-081.36E-09-1.64E-05
        SQP
        Land use related impacts/Soil quality
        -1.08E+039.38E+014.19E+021.59E+035.11E+012.37E+004.36E+001.99E+003.24E+011.26E+020.00E+004.74E+006.62E-017.09E+00-5.76E+02

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ5.26E+021.01E+008.83E+016.15E+027.13E-016.48E-012.01E+003.14E-015.90E+006.07E+010.00E+005.11E-021.88E-014.77E-02-2.32E+02
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ5.26E+021.01E+008.83E+016.15E+027.13E-016.48E-012.01E+003.14E-015.90E+006.07E+010.00E+005.11E-021.88E-014.77E-02-2.32E+02
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ2.31E+037.95E+011.13E+022.50E+031.06E+021.86E+019.45E+001.33E+002.72E+013.33E+020.00E+003.99E+001.93E+002.86E+00-1.21E+03
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ2.31E+037.95E+011.13E+022.50E+031.06E+021.86E+019.45E+001.33E+002.72E+013.33E+020.00E+003.99E+001.93E+002.86E+00-1.21E+03
        SM
        Secondary material
        kg1.23E-010.00E+000.00E+001.23E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ8.38E-040.00E+000.00E+008.38E-040.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ5.39E-020.00E+000.00E+005.39E-020.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³1.68E+001.70E-023.75E-021.74E+001.36E-022.05E-026.82E-030.00E+006.14E-028.18E-020.00E+008.18E-046.82E-033.41E-03-6.72E-01

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg6.53E+000.00E+000.00E+006.53E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg4.25E+000.00E+001.20E+011.63E+010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg5.42E-030.00E+000.00E+005.42E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg2.11E-030.00E+000.00E+002.11E-030.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+003.65E+010.00E+000.00E+00
        MER
        Materials for energy recovery
        kg9.30E-060.00E+000.00E+009.30E-060.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+002.88E+000.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00