Fan Coils
product logo

KaDeck

Versatile air conditioning for existing and new-build offices.
KaDeck

Overview

References

Hotel Ross, Meissen

Hotel Ross, Meissen

continue
Eurotheum, Frankfurt am Main

Eurotheum, Frankfurt am Main

continue
Residential/office complex, Heilbronn

Residential/office complex, Heilbronn

continue
Hotel Star Inn, Heidelberg

Hotel Star Inn, Heidelberg

continue
Hotel Looken Inn, Lingen

Hotel Looken Inn, Lingen

continue

Product Selection

Your search resulted in 20 hits

Unit design Installation site Air outlet

Cooling output (dry)1)

(W)

Cooling output (wet)2)

(W)

Heat output3)

(W)

Sound pressure level4)

(dB(A))

Control option Calculation
Dry cooling Suspended ceiling One-sided discharge 275 – 896 1146 – 3744 20 – 37 Without built-in control Calculate
Dry cooling Suspended ceiling Bidirectional discharge 540 – 1558 2253 – 6514 23 – 40 KaControl with dewpoint monitor sensor Calculate
Dry cooling Suspended ceiling Bidirectional discharge 540 – 1558 2253 – 6514 23 – 40 KaControl without dewpoint monitor sensor Calculate
Dry cooling Suspended ceiling Bidirectional discharge 540 – 1558 2253 – 6514 23 – 40 Without built-in control Calculate
Wet cooling Suspended ceiling One-sided discharge 579 – 1570 950 – 2876 < 20 – 35 KaControl with condensate pump Calculate
Wet cooling Suspended ceiling One-sided discharge 579 – 1570 950 – 2876 < 20 – 35 Without built-in control, with condensate pump Calculate
Wet cooling Suspended ceiling Bidirectional discharge 968 – 3050 1519 – 5248 21 – 38 KaControl with condensate pump Calculate
Wet cooling Suspended ceiling Bidirectional discharge 968 – 3050 1519 – 5248 21 – 38 Without built-in control, with condensate pump Calculate

1)At CHW 16/18, tL1 =27 °C, 48% relative humidity

2)At CHW 7/12 °C, tL1 = 27 °C, 48% relative humidity

3)At LPHW 75/65 °C, tL1 = 20 °C

4)The sound pressure levels were calculated with an assumed room insulation of 8 dB(A).

Downloads

Declarations/Certificates
TÜV Certificate ISO 9001:2008
PDF (132 kB)
EU Declaration of Conformity KaDeck fan coils (FCU)
PDF (1 MB)
Cross-product information
Kampmann hotel references
PDF (6.2 MB)
Spezial hotels
PDF (2.8 MB)
Overview products, products international
PDF (4.6 MB)
Spezial retail chains
PDF (3.4 MB)
Spezial office and commercial building
PDF (2.7 MB)
Spezial Warehouses and logistics buildings
PDF (830 kB)
BIM data (Building Information Modeling)
Kampmann GmbH BIM data
Installation manuals
KaDeck fan coils (FCU)
PDF (8.8 MB)
Prices
Kampmann Price List 2019
PDF (15.4 MB)
Technical catalogues
KaDeck fan coils (FCU)
PDF (2.8 MB)
CAD-Drawings
KaDeck views
PDF (81 kB)
KaDeck views
DXF (5.9 MB)
KaDeck views
DWG (490 kB)
Leaflets/Flyers
Spezial KaDeck
PDF (1.7 MB)