• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
      • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Katherm HK
          • Katherm QK
          • Katherm QK nano
          • Katherm NK
          • Katherm QL
          • Katherm ID
          • Katherm QE
        • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • TIP
          • TOP
          • Ultra
          • Ultra Allround
          • TOP C
          • Site heater
          • Ultra DX
          • Resistent
        • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Venkon
          • KaCool D AF
          • Ultra
          • KaDius
          • Ultra Allround
          • KaDeck
          • PowerKon LT
          • Venkon XL
          • KaCool W
          • Venkon DX
          • KaCool D HY
          • KaCool D HC
        • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
          • PowerKon LT
        • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Slot diffusers
          • Round/oval duct diffusers
          • Combination diffusers
          • Swirl diffusers
          • Displacement diffusers
          • Industrial diffusers
        • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • KaCompact KG
        • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • UniLine
          • Cassette UniLine
          • Tandem
          • UniLine DX
          • Tandem - Cassette Version
          • Tandem DX
          • ProtecTor
        • Perimeter Heating
        • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • WZA
          • UZS
        • Heat pumps and chillers
        • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Optiline
          • Wooden grilles
      • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Download Centre
        • Calculation programs
        • Hall Heating Tool
        • Air Volume Flow Calculator
        • NC- and NR-Level Calculator
      • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Customer Service
        • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Consultation
          • Design
          • Site Measurement
          • Construction including Tailored Solutions
          • Delivery
          • Installation
      • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
        • The Kampmann Group
        • Research and Development
        • Sustainability and Quality
        • Compliance
      • Career
      • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
        • News
        • Technology and Knowledge
        • Interviews
      • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Find Contact
        • Contact Form
      • Home
      • Products
      • Fan Coils
      • KaCool W
      • 324001212000C1

      Products

      • Trench Technology
      • Unit Heaters
      • Fan Coils
      • Heat pump-based heater
      • Diffusers
      • Air Handling Units
      • Door Air Curtains
      • Perimeter Heating
      • Decentralised Ventilation Units
      • Heat pumps and chillers

      Company

      • The Kampmann Group
      • Research and Development
      • Sustainability
      • Magazine

      Service

      • Project Support
      • Customer Service
      • Contact

      Career

      • Career with Kampmann

      Contact

      +49 591 7108-8020info@kampmanngroup.com
      • Imprint
      • Kampmann Group - General Terms and Conditions
      • Kampmann Group - General Terms and Conditions of purchase
      • Central Data Protection Instruction
      • Cookies
      • Reporting system
      • Modern Slavery Statement
      • Compliance

      Our products are intended exclusively for B2B sales.

      KaCool W

      Article no.: 324001212000C1
      1,613.00 EUR
      no VAT.
      • Details
      • Description
      • Technical data
      • Acoustic data
      • EPD
      • Dimensions
      • Accessories
      • BIM
      • Downloads

      basic unit

      Kampmann KaCool W wall-mounted fan coil with attractive design for the air conditioning of rooms. The flat screen (185 mm) made of a combination of metal and plastic impresses with its simple appearance in RAL 9016 matt (traffic white).
      The cover can be attached and removed using two screws. Without the panel, all components are accessible. Adjustable fins ventilate the air into the room in a targeted manner. A regenerable ISO COARSE 30% (G2) air filter is fitted on the upper air extraction system, which can be inserted and removed without the need for tools.
      To mount the unit, the basic unit is mounted to the wall without a visible panel using the drilling template supplied. The water and electrical lines are then connected. The user-friendly design of the unit and accessibility to relevant components reduce installation time, maintenance and cleaning. The valve kits or condensate pump, which can be supplied separately as accessories, are located within the unit to maintain the aesthetic of the wall-mounted chilled water unit. Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.6,08E+01. Further calculations possible online.

      Heat exchanger

      High-output heat exchanger, consisting of round copper tubes with aluminium fins, suitable for use with LPHW.
      System2-pipe
      Max. operating pressurebar8
      Max. entering water temperature°C75
      Min. entering water temperature°C6
      Max. air inlet temp.°C30
      Max. glycol volume%50

      Condensate tray

      condensate tray made of ABS material

      Fan

      Tangential fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired. Integral thermal contact. Motor fault: Automatic motor shut-off in the event of a fault.
      Protection class IP44

      Control

      KaControl C1 control system factory fitted and wired. Controlled via a separate operating unit in the room as a master unit or for use as a slave unit.
      Room control for up to six devices via KaController, expandable to up to 30 devices via CANbus interface (CANbus card required)
      • Slot for optional interfaces:
      • CANbus/Modbus/KNX card
      • Temperature measurement optionally via sensor in the room control unit or external room temperature sensor
      • With integrated and configured air intake temperature sensor for optimum detection of the air intake or room temperature
      • One digital input configurable for:
      • Device On/Off
      • Comfort/Economy mode switch
      • Heating/Cooling changeover
      • Window contact, presence detector contact
      • Card reader contact
      • Output for the continuous (0-100%) control of the EC fan Night mode (energy-saving mode) that can be activated via a timer program in the KaController or room frost control activated via digital input. Five-stage fan control 1-2-3-4-5 Demand--led automatic fan mode with continuous (0-100 %) fan control, switch-off in the event of a fault.

      Configuration

      Model size1
      Water connectionsleft
      Filter classISO Coarse 30% filter (G2)
      Widthmm185
      Heightmm333
      Lengthmm930
      Weightkg13.0
      Connection1/2 inch

      Design wall-mounted unit

      • Comfortable heating and cooling with a design panel of only 185 mm
      • includes all components and accessories within the panel
      • for both residential and non-residential buildings
      • Heat pump compatible
      • fulfills the requirements of VDI 6022

      design trim

      • Combination of plastic and metal in RAL 9016 matt
      • The valve kits and condensate pump are mounted inside the design panel and are therefore invisible from the outside

      Heat exchanger

      • High-performance copper-aluminum heat exchanger
      • with high heating and cooling output Flow-optimized

      durable EC tangential fan

      • Noise-optimized, stepless and energy-saving EC motor
      • Horizontal tangential fan made of plastic

      Air filter

      • Easy removal possible
      • Regeneration of the ISO Coarse air filter by simple suction

      View

      • IFront view
      • IIside view
      • IIIcross-section
      • IVtop view
      • VView from below

      Further Information

      • 1Return
      • 2Flow
      • 3Condensate tray
      • 4condensate drain

      Specifications

      Model size1
      Weight13.0 kg
      Water content0.8 l
      Connection1/2 inch
      Water connectionsleft
      Dimension (A)929 mm
      Dimension (B)625 mm
      Dimension (C)629 mm

      We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

      Basic data

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      GWP - Total
      Climate change - total
      kg CO2 eq5.88E+011.38E+006.05E-016.08E+011.86E+001.00E+001.24E+005.39E-012.15E+012.68E+020.00E+006.01E-022.65E-022.61E+00-1.78E+01
      GWP - fossil
      Climate change - fossil
      kg CO2 eq5.86E+011.38E+001.16E+006.11E+011.86E+004.08E-011.19E+004.60E-012.14E+012.68E+020.00E+006.01E-022.65E-022.61E+00-1.77E+01
      GWP - Biogenic
      Climate change - biogenic
      kg CO2 eq0.00E+000.00E+00-5.94E-01-5.94E-010.00E+005.94E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      GWP - Luluc
      Climate change - land use and land use change
      kg CO2 eq2.23E-015.12E-043.46E-022.58E-012.98E-042.80E-045.19E-027.95E-027.99E-024.66E-010.00E+002.24E-051.50E-052.12E-05-1.30E-01
      ODP
      Ozone Depletion
      kg CFC-11 eq9.26E-073.12E-082.72E-089.84E-073.19E-081.02E-082.14E-081.06E-084.75E-072.67E-060.00E+001.36E-093.56E-101.51E-09-2.07E-07
      AP
      Acidification
      mol H+ eq1.26E+003.38E-031.09E-021.28E+007.15E-031.59E-035.50E-037.84E-037.02E-015.87E-010.00E+001.46E-041.86E-047.22E-04-1.98E-01
      EP - Freshwater
      Eutrophication aquatic freshwater
      kg P eq1.10E-011.00E-045.81E-041.10E-015.74E-051.93E-041.05E-031.57E-046.17E-023.94E-010.00E+004.40E-061.16E-059.48E-06-1.32E-02
      EP - Marine
      Eutrophication aquatic marine
      kg P eq9.30E-028.93E-044.55E-039.85E-022.67E-038.16E-041.80E-031.16E-034.75E-021.99E-010.00E+003.84E-058.45E-052.72E-03-1.81E-02
      EP - Terrestrial
      Eutrophication terrestrial
      mol N eq1.14E+009.67E-033.94E-021.19E+002.92E-023.77E-031.21E-024.87E-036.02E-011.35E+000.00E+004.16E-049.02E-043.49E-03-2.03E-01
      POCP
      Photochemical ozone formation
      kg NMVOC3.74E-015.63E-037.13E-033.87E-011.03E-021.99E-033.57E-032.30E-031.88E-013.81E-010.00E+002.44E-042.69E-049.77E-04-7.21E-02
      ADPE
      Depletion of abiotic resources - minerals and metals
      kg Sb eq1.58E-023.98E-066.59E-061.58E-021.85E-062.58E-067.71E-063.69E-061.07E-024.52E-040.00E+001.75E-071.93E-081.52E-07-1.70E-03
      ADPF
      Abiotic resource depletion - fossil fuels
      MJ8.43E+022.09E+011.82E+018.82E+022.56E+018.07E+001.87E+016.58E+002.82E+024.02E+030.00E+009.12E-013.59E-011.03E+00-2.28E+02
      WDP
      Water use
      m³ depriv.4.36E+011.18E-013.09E+004.68E+017.82E-029.55E-028.83E-014.10E-011.69E+014.76E+010.00E+005.18E-032.05E-03-1.25E-01-1.21E+01
      GWP-GHG
      Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
      kg CO2 eq5.88E+011.38E+001.20E+006.14E+011.86E+004.08E-011.24E+005.39E-012.15E+012.68E+020.00E+006.01E-022.65E-022.61E+00-1.78E+01
      PM
      Particulate Matter emissions
      disease inc.5.26E-061.36E-071.53E-075.55E-066.48E-082.16E-085.32E-083.75E-082.28E-062.53E-060.00E+005.96E-094.91E-096.72E-09-1.35E-06
      IR
      Ionizing radiation, human health
      kBq U-235 eq5.95E+002.33E-022.60E-016.24E+001.36E-024.35E-021.56E-013.82E-022.60E+005.80E+010.00E+001.02E-031.73E-032.69E-03-1.98E+00
      ETP - FW
      Ecotoxicity (fresh water)
      CTUe1.48E+032.44E+001.37E+011.49E+031.69E+003.54E+001.02E+018.15E+001.01E+037.39E+020.00E+001.07E-013.40E-022.11E+01-1.30E+02
      HTP - C
      Human toxicity, cancer effects
      CTUh1.51E-072.29E-101.11E-091.52E-071.71E-103.25E-108.64E-103.54E-107.89E-083.38E-080.00E+001.00E-112.88E-123.08E-10-4.00E-08
      HTP - NC
      Human toxicity, non-cancer effects
      CTUh1.15E-051.34E-082.68E-081.15E-051.85E-084.95E-091.04E-085.03E-096.87E-061.60E-060.00E+005.86E-107.52E-111.32E-08-1.80E-06
      SQP
      Land use related impacts/Soil quality
      -4.54E+022.09E+017.48E+015.50E+029.05E+001.58E+001.16E+011.15E+012.53E+025.57E+020.00E+009.16E-013.19E-021.63E+00-6.92E+01

      Resource use

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      PERE
      Use of renewable primary energy excluding resources used as raw materials
      MJ1.33E+023.21E-011.71E+011.51E+021.84E-015.90E-015.38E+001.63E+005.70E+018.21E+020.00E+001.41E-022.45E-024.19E-02-4.24E+01
      PERM
      Use of renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PERT
      Total use of renewable primary energy
      MJ1.33E+023.21E-011.71E+011.51E+021.84E-015.90E-015.38E+001.63E+005.70E+018.21E+020.00E+001.41E-022.45E-024.19E-02-4.24E+01
      PENRE
      Use of non-renewable primary energy excluding resources used as raw materials
      MJ8.43E+022.09E+011.82E+018.83E+022.56E+018.07E+001.88E+016.80E+002.82E+024.02E+030.00E+009.12E-013.59E-011.03E+00-2.28E+02
      PENRM
      Use of non-renewable primary energy resources used as raw materials
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PENRT
      Total use of non-renewable primary energy
      MJ8.43E+022.09E+011.82E+018.83E+022.56E+018.07E+001.88E+016.80E+002.82E+024.02E+030.00E+009.12E-013.59E-011.03E+00-2.28E+02
      SM
      Secondary material
      kg2.18E+008.79E-031.42E+003.60E+005.05E-031.98E-023.96E-039.05E-035.88E-014.95E-010.00E+003.85E-041.16E-046.67E-04-1.82E+00
      RSF
      Renewable secondary fuels
      MJ3.77E-021.16E-046.94E-034.48E-025.27E-059.59E-049.15E-051.12E-043.59E-033.68E-030.00E+005.08E-063.71E-071.88E-05-7.38E-04
      NRSF
      Non-renewable secondary fuels
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      FW
      Net use of fresh water
      m³1.07E+002.91E-037.28E-021.15E+001.91E-032.51E-032.12E-029.71E-034.19E-011.30E+000.00E+001.27E-045.37E-05-2.88E-03-2.93E-01

      Waste & Output Flows

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      HWD
      Hazardous waste disposed
      kg1.51E+013.04E-029.26E-021.53E+011.88E-029.94E-028.12E-021.02E-015.28E+009.91E+000.00E+001.33E-035.54E-044.60E-01-2.79E+00
      NHWD
      Non-hazardous waste disposed
      kg4.54E+026.19E-012.88E+004.58E+023.67E-015.06E+006.33E+004.86E+002.45E+021.92E+030.00E+002.71E-025.77E-029.04E+00-7.84E+01
      RWD
      Radioactive waste disposed
      kg1.54E-035.72E-066.65E-051.61E-033.33E-061.11E-054.48E-059.75E-066.63E-041.72E-020.00E+002.51E-075.06E-076.52E-07-5.21E-04
      CRU
      Components for reuse
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      MFR
      Material for recycling
      kg7.74E-022.58E-041.70E-037.93E-023.36E-041.16E-032.26E-032.89E-044.02E-025.97E-010.00E+001.10E-051.78E-054.76E-03-1.78E-02
      MER
      Materials for energy recovery
      kg1.85E-049.19E-076.30E-048.16E-045.19E-071.05E-061.73E-034.68E-078.71E-054.20E-050.00E+004.03E-084.68E-093.99E-08-1.23E-05
      EE (Electrical)
      Exported energy electrical
      MJ6.73E-013.50E-034.43E-027.21E-011.85E-037.25E-031.15E-016.94E-031.92E-015.26E+010.00E+001.54E-041.48E-033.02E-03-5.23E-02
      EE (Thermal)
      Exported energy thermal
      MJ5.81E-013.73E-033.80E-035.88E-012.16E-034.47E-032.55E-021.45E-016.23E-013.05E-010.00E+001.63E-041.40E-052.51E-03-1.29E+00