basic unit
Kampmann KaCool W wall-mounted fan coil with attractive design for the air conditioning of rooms. The flat screen (185 mm) made of a combination of metal and plastic impresses with its simple appearance in RAL 9016 matt (traffic white).
The cover can be attached and removed using two screws. Without the panel, all components are accessible. Adjustable fins ventilate the air into the room in a targeted manner. A regenerable ISO COARSE 30% (G2) air filter is fitted on the upper air extraction system, which can be inserted and removed without the need for tools.
To mount the unit, the basic unit is mounted to the wall without a visible panel using the drilling template supplied. The water and electrical lines are then connected. The user-friendly design of the unit and accessibility to relevant components reduce installation time, maintenance and cleaning. The valve kits or condensate pump, which can be supplied separately as accessories, are located within the unit to maintain the aesthetic of the wall-mounted chilled water unit. Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.6,08E+01. Further calculations possible online.
Heat exchanger
High-output heat exchanger, consisting of round copper tubes with aluminium fins, suitable for use with LPHW.
| System | | 2-pipe |
| Max. operating pressure | bar | 8 |
| Max. entering water temperature | °C | 75 |
| Min. entering water temperature | °C | 6 |
| Max. air inlet temp. | °C | 30 |
| Max. glycol volume | % | 50 |
Condensate tray
condensate tray made of ABS material
Fan
Tangential fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired. Integral thermal contact. Motor fault: Automatic motor shut-off in the event of a fault.
Control
KaControl C1 control system factory fitted and wired. Controlled via a separate operating unit in the room as a master unit or for use as a slave unit.
Room control for up to six devices via KaController, expandable to up to 30 devices via CANbus interface (CANbus card required)
- Slot for optional interfaces:
- CANbus/Modbus/KNX card
- Temperature measurement optionally via sensor in the room control unit or external room temperature sensor
- With integrated and configured air intake temperature sensor for optimum detection of the air intake or room temperature
- One digital input configurable for:
- Device On/Off
- Comfort/Economy mode switch
- Heating/Cooling changeover
- Window contact, presence detector contact
- Card reader contact
- Output for the continuous (0-100%) control of the EC fan Night mode (energy-saving mode) that can be activated via a timer program in the KaController or room frost control activated via digital input. Five-stage fan control 1-2-3-4-5 Demand--led automatic fan mode with continuous (0-100 %) fan control, switch-off in the event of a fault.
Configuration
| Model size | | 1 |
| Water connections | | left |
| Filter class | | ISO Coarse 30% filter (G2) |
| Width | mm | 185 |
| Height | mm | 333 |
| Length | mm | 930 |
| Weight | kg | 13.0 |
| Connection | | 1/2 inch |