• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Heat pumps and chillers
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        KaClima S

        Air conditioning solution for power range 4 - 15 kW.

        • Heating
        • Cooling
        Product image
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        EC fan

        • Durable, noise-optimized EC fan
        • Stepless control for optimum control of the air volume

        Efficiency

        • Heat pumps work very efficiently.
        • They can generate over 4 kW of heat from 1 kW of electricity, depending on the outside temperatures.

        cooling function

        • An integrated cooling function for summer operation is available as standard.

        future-proof refrigerant R290

        • Future-proof air conditioning solution with the refrigerant R290 (propane (R290))
        • Very low GWP value of 0.02
        • R290 does not fall under the category of F-gases and is therefore not affected by the phase-down or bans
        • Low refrigerant charge quantities, which help to reduce the environmental impact.

        Refrigerant

        There are different refrigerants to choose from. This means that heat pumps can be selected specifically according to the type of refrigerant used in order to find suitable solutions that meet individual requirements in terms of environmental compatibility, efficiency and safety.

        Refrigerant
        R290

        Unit design

        There are different operating modes to choose from.

        Heat pumps and chillers can be selected specifically according to their "heating and cooling" or "cooling only " function in order to find suitable solutions in line with individual requirements in terms of comfort, application area and operating mode.

        Unit design
        Cooling and Heating

        Model size

        The units are available in several model sizes to allow the output to be tailored to requirements.

        The model size is selected depending on the required thermal performance and noise requirements.

        Larger model sizes offer higher performance, but are associated with larger housing dimensions, which must be taken into account during planning.

        Model size
        21
        31
        41
        51
        61
        71
        81

        Installation

        • The installation must comply with the applicable regulations.
        • The surface must be load-bearing and designed for the weight of the units.
        • The functional clearances around the machine must be observed.
        • We recommend setting up the units at a distance of at least 20 cm from the ground (or expected snow depth).
        • The units are intended exclusively for outdoor installation.
        • The location must be planned in such a way that it is easily accessible for installation, Maintenance and repairs.

        Air stream

        • The air flow over the register must be free.
        • Perfect air circulation is essential to ensure trouble-free operation of the machine.

        The following points should be avoided:

        • Obstacles in the air flow
        • Insufficient air exchange
        • Leaves or other soiling that can clog the heat exchanger.
        • Strong wind that impairs or uncontrollably increases the air flow through the register.
        • Heat sources or sources of soiling near the unit (e.g. chimneys, ventilation outlets)
        • Stratification phenomena (cold air accumulating on the ground)
        • Air short circuit (expelled air that is sucked in again)
        • High, enclosing walls and installation under protective roofs or in corners where stratification or air short circuits may occur.

        Disregarding these instructions can lead to the following problems:

        • Reducing energy efficiency
        • Malfunctions due to high or low pressure

        Sound

        • The sound pressure level is specified in free field at a distance of 1 meter from the outer surface of the unit during operation.
        • The noise levels are determined using the tensiometric method (UNI EN ISO 9614-2).

        The data refer to the following conditions for heating (units with heat pump function):

        • Water temperatures: 35/30 °C
        • Ambient temperature: 7 °C

        The data refer to the following conditions for cooling:

        • Water temperatures: 7/12 °C
        • Ambient temperature: 35 °C

        Hydraulics

        • The hydraulics must be planned in such a way that the minimum water circulation of the machine is guaranteed at all times.
        • The minimum water volume in the overall hydraulics of the heat pump / heat pump cascade must be maintained and be available to the systems at all times.

        Flammable refrigerants

        • The installation guidelines for flammable refrigerants in the installation instructions must be observed.
        • The corresponding documents for the S and M series are available in the download area.
        • Special requirements must be observed and complied with for systems with the refrigerant R290.
        • In general, the specifications of EN 378 must be observed and tested.

        Electrical connection

        • The electrical connection of the heat pumps must be planned according to the maximum connected load of the machine.
        • For large connected loads, this must be agreed with the energy supplier.