Unit Heaters
Ultra
Article no.:
154000842058C1
List price
2,555.00 €
plus VAT
Overview
- Continuously variable EC single-phase whisper-quiet sickle-blade fan (see Fig.)
- High-efficiency due to the aerodynamic design of the rotor housing
- Motor protection class IP 54
- According to DIN ISO 21940-11 for the corresponding fan category; the external rotor motor integrated in the fan impeller is balanced according to ISO 14694
- External rotor motor integrated in the fan impeller
- Complies with Directive (EU) 327/2011 ("LOT 11")
- Heating: low-temperature version for operation with very low water temperatures
- Cooling: highest possible cooling output even with dry cooling by means of round large-surface heat exchanger
Ultra-efficient as a component in a hybrid system: while the Ultra has decentralised temperature control, an air handling unit with small dimensions deals with ventilation and heat recovery. This saves operating costs as all components only work when demand is detected. And you benefit from the reduced size of the air handling unit in terms of investment and installation.
- Ease of access by snap-lock quick-release closure and positioning aid
- External pump sump for visual control through the outlet grille
- Float switch easily accessible – without the need to dismantle the base and condensation tray
- Energy-saving condensate pump even more powerful and quieter with a delivery height of up to 8 m
- Controlled flow of residual water during maintenance – outlet connector in the pump sump
Housing with base cover easily removable for maintenance
The air flows out through six air discharge openings and is guided through air guidance fins. A grid defines their adjustment into six positions.
Accessories
Control accessories KaControl
KaController
with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210001
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210001
List price
222.00 €
plus VAT
KaController
with one-button operation, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9017 traffic black, made of resistant PVC, Type 3210006
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210006
List price
222.00 €
plus VAT
KaController
with side operating keys, 24 V wall-mounted room control unit, with integral room temperature sensor, Protection class IP 30, Temperature setting range 8 - 35 °C, Colour similar to RAL 9010 pure white, made of resistant PVC, Type 3210002
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003210002
List price
222.00 €
plus VAT
Industry KaController
industrial housing with hinged transparent cover, lockable, with side operating keys, Surface-mounted, Protection class IP 65, Colour grey, made of plastic, Type 3214002
Suitable for: all units with control option KaControl -C1, ProtecTor Door Air Curtains
Suitable for: all units with control option KaControl -C1, ProtecTor Door Air Curtains
Article no.:
196003214002
List price
800.00 €
plus VAT
Room temperature sensor
Wall-mounted, Surface-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, made of plastic, Type 3250110
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250110
List price
58.00 €
plus VAT
Outside temperature sensor/industrial temperature sensor
Surface-mounted, Protection class IP 65, Colour similar to RAL 9010 pure white, Type 3250112
Suitable for: all units with control option KaControl -C1, ProtecTor Door Air Curtains
Suitable for: all units with control option KaControl -C1, ProtecTor Door Air Curtains
Article no.:
196003250112
List price
58.00 €
plus VAT
Clip-on pipe sensor
to detect the medium temperature, Protection class IP 67, Temperature setting range -20 - 70 °C, Colour black, Type 3250115
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
heating/cooling changeover function only in conjunction with 3-way valve!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
Article no.:
196003250115
List price
56.00 €
plus VAT
Serial KNX card
for integration into a KNX/EIB network, interface PCOS00KXN0, Type 3260702
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Article no.:
196003260702
List price
362.00 €
plus VAT
Serial CANbus card
to increase the number of units in a single-circuit system from 7 to a maximum of 30 units, one required per unit, Extension of the cable length from the first to the last unit from 30 m to 500 m, Can only be used with the KaControl -C1 control version!The room temperature cannot be recorded by a room sensor when using CanBus cards., Type 3260301
Suitable for: all units with control option KaControl -C1
Suitable for: all units with control option KaControl -C1
Article no.:
196003260301
List price
125.00 €
plus VAT
Serial Modbus card
Type 3260101
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: all units with control option KaControl -C1
Article no.:
196003260101
List price
117.00 €
plus VAT
Valves
Thermoelectric shut-off valve
as a straight valve body with thermoelectric actuator 24 V AC/DC, 24 V AC/DC, Connection 1'' kvs value 3.3 m³/h, Max. operating pressure 10 bar, Type 30931
Only in conjunction with a KaControl controller!
Only in conjunction with a KaControl controller!
Article no.:
196000030931
List price
162.00 €
plus VAT
Control shut-off valve
24 V AC/DC, for automatic flow and temperature control, Connection 1'' kvs value 3.1 m³/h, Max. operating pressure 25 bar, Type 30980
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, min. flow volume 250 l/h, max. flow volume 1800 l/h, DN 20
Suitable for: Model size 4 - 5, TOP or Ultra Unit Heaters, min. flow volume 250 l/h, max. flow volume 1800 l/h, DN 20
Article no.:
196000030980
List price
252.00 €
plus VAT
Control shut-off valve
24 V AC/DC, for automatic flow and temperature control, Connection 1'' kvs value 4.1 m³/h, Max. operating pressure 25 bar, Type 30981
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, min. flow volume 400 l/h, max. flow volume 2500 l/h, DN 25
Suitable for: Model size 4 - 6, TOP or Ultra Unit Heaters, min. flow volume 400 l/h, max. flow volume 2500 l/h, DN 25
Article no.:
196000030981
List price
355.00 €
plus VAT
Repair switch
Repair switch
Enables individual units in a switching group to be decommissioned by voltage disconnection. The thermal contacts are bridged in advance, and subsequently opened on the motor side so that the other units in the group can continue to operate without interruption., EC, Protection class IP 65, 25 A, supplied separately, Type 30160
Suitable for: all unit heaters, air curtains with EC-motors
Suitable for: all unit heaters, air curtains with EC-motors
Article no.:
196000030160
List price
103.00 €
plus VAT
Filter
calculation-relevant accessory
Recirculating air filter element
calculation-relevant accessory
for direct mounting on the unit inlet with recirculation air units, ISO Coarse 45% (G3) filter
Cannot be used with under-ceiling units!
Suitable for: Model size 73 - 84
Cannot be used with under-ceiling units!
Suitable for: Model size 73 - 84
Article no.:
154000064050
List price
73.00 €
plus VAT
Panel/grille
Recirculating air grille
Grid dimensions 625 x 625 mm, powder coated, Colour RAL 9016 traffic-white
Suitable for: Model size 73 - 96
Suitable for: Model size 73 - 96
Article no.:
154000060988
List price
675.00 €
plus VAT
Additional colours
surcharge for RAL colour of your choice
matt gloss level
Price per unit.
Suitable for: Ultra Unit Heaters
Price per unit.
Suitable for: Ultra Unit Heaters
Article no.:
154007010022
List price
823.00 €
plus VAT
Downloads
Declarations/Certificates
Certificate ISO 50001:2018
PDF
(194 kB)
Certificate ISO 9001:2008
PDF
(118 kB)
EU Declaration of Conformity for unit heaters
PDF
(369 kB)
ErP data sheet 2016-2281 for Ultra unit heater
PDF
(97 kB)
ErP data sheet 1253-2014 for Ultra unit heater
PDF
(233 kB)
Digital EPD database
EPD Ultra size 84
PDF
(1.3 MB)
Technical catalogues
Ultra unit heaters
PDF
(7.7 MB)
CAD-Drawings
Ultra unit heaters, heating [mm]
PDF
(354 kB)
Ultra unit heaters, heating or cooling [mm]
PDF
(318 kB)
Ultra unit heaters, heating [Inch]
PDF
(329 kB)
Ultra unit heaters, heating or cooling [Inch]
PDF
(292 kB)
Ultra unit heaters, heating [Inch]
DXF
(10.8 MB)
Ultra unit heaters, heating or cooling [Inch]
DWG
(1.4 MB)
Ultra unit heaters, heating [Inch]
DWG
(1.4 MB)
Ultra unit heaters, heating or cooling [mm]
DWG
(1.9 MB)
Ultra unit heaters, heating [mm]
DWG
(2 MB)
Ultra unit heaters, heating or cooling [Inch]
DXF
(10.3 MB)
Ultra unit heaters, heating [mm]
DXF
(14.8 MB)
Ultra unit heaters, heating or cooling [mm]
DXF
(14.3 MB)
Cross-product information
ErP: Consequences forventilation systems
PDF
(243 kB)
Brochure Unit Heaters
PDF
(2.3 MB)
BIM data (Building Information Modeling)
Kampmann Group BIM data
Manuals
Ultra unit heaters
PDF
(4.8 MB)
Ultra unit heaters, brief instructions
PDF
(2.1 MB)
Installation plans
Ultra, KaControl version
PDF
(501 kB)