        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm QK nano
        • 442170722249M1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm QK nano

        Article no.: 442170722249M1
        3,000.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • BIM
        • Downloads

        Basic unit

        Kampmann Katherm QK nano trench heater, low height, supplied as a ready-to-install heating trench in the floor, convector-based with tangential fan-assisted convection. Heat outputs tested in accordance with DIN EN 16430, parts 1 and 2.
        Floor trench made of sendzimir galvanized sheet steel, painted graphite grey. Height adjustment feet on the side to adjust the trench height, fitted with impact sound insulation, raised floor height adjustment feet with impact noise insulation. With cross struts to reinforce the floor trench. With pre-punched connection openings for water flow and return pipes and electrical connection, room-side. With frame insert profile, colour-coordinated with the grille. Features standard protective installation cover and frame trim. With a cover plate over the connection area.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.1,44E+01. Further calculations possible online.

        Heat exchanger

        High-output heat exchanger made of round copper pipes with aluminium fins including anti-twist mechanism, painted graphite-grey. With air baffle. With integral bleed option.
        System2-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C95
        Min. entering water temperature°C15
        Max. air inlet temp.°C40

        Fan

        Tangential fan with safety guard. Energy-saving EC fan with 0-10 V signal for continuously variable speed control. All rotating parts are silent and mounted on maintenance-free bearings. Motor monitoring with internal fault processing. Factory-wired.

        Control

        • Built-in KaControl MC controller for continuous fan control with motor monitoring.
        • For the control of 24 V DC actuators (Open/Closed) for heating and cooling operation.
        • With connection option for 5 multifunctional inputs (room temperature, window contact, supply and return temperature, heating/cooling changeover, condensate alarm, sequential control via a 0-10 V signal etc.), unit-specific control and regulation algorithms with the core functions of room temperature control (heating/cooling).
        • Timer program with battery-backed real-time clock for four operating modes (Day/Eco/Extra/Off), commissioning function.
        • Grouping of up to 10 units and a display to create a control zone using CAN-bus, automatic addressing and communication monitoring of all bus subscribers, continuous synchronisation of all statuses and parameters within the group.
        • CAN bus interface and galvanically isolated RS485 interface, each with two terminal blocks for separate connection with daisy chain cabling with a switchable terminal resistor.
        • Ethernet interface with two RJ45 sockets with built-in switching function.
        • KNX-TP interface with socket terminal, all terminals are designed as plugs, wireless communication via Wi-Fi web server for user-friendly operation and for complete password-protected parametrisation.
        • protocols can be unlocked via licences: BACnet/IP, Modbus TCP, Modbus RTU, KNX.
        • Built-in 24 V DC current measurement.

        Grille

        With FineLine grille made from solid triangular profiles with support profiles, rigid construction.

        Configuration

        Grille designOrthogonal grille
        Grille finishSteel, coated RAL 9005
        Lengthmm2700
        Widthmm165
        Heightmm70
        Bar heightmm4
        Bar depthmm2
        Bar spacingmm5
        Free area, approx. %70
        Weightkg4.3
        • Connectionleft

        Heating with the smallest dimensions

        • Use in rooms with low floor structures and increased heat requirements
        • Energy-saving heating operation for LPHW and heat pump operation
        • with very quiet running EC tangential fans
        • Quick fixing thanks to mounting bracket with simultaneous sound decoupling
        • Prefabricated for easy hydraulics connection
        • Ready-to-connect control systems and integration in BMS systems
        • Specially developed filigree FineLine grating with flow-optimized triangular profiles; in transverse or linear form and various material and colour versions
        • Cover plates for privacy and protection against soiling
        • Life cycle assessment data (EPD) available for building sustainability certification

        Slip joints possible

        • Detachable headpiece
        • for easy coupling of the trench convectors

        EC tangential fan

        • for uniform air flow through the convectors
        • Robust motor design
        • Stepless speed control via an external 0 - 10 V signal

        Heat exchanger

        • Heat exchanger made from proven copper/aluminum combination
        • Optimized for air flow and heat dissipation
        • graphite-grey coated
        • An anti-twist device prevents damage to the convectors when installing the valves.

        Installation

        • Step-stable height adjustment for secure elevation of the trench convector with plastic cap for sound decoupling
        • Mounting bracket for easy fixing of the trench convectors with rubber carpet pad for sound decoupling

        Connection area

        • 1/2" female thread connection for quick connection
        • space-saving
        • for valves and electrical components
        • With cover plate as privacy screen and protection against soiling

        • IFront view
        • IIside view
        • IIItop view (without cover panel)
        • IVCross-section, enlarged

        • 1window side
        • 2room side

        Article no.442170722249M1
        Height70 mm
        Width165 mm
        Length (A)2,700 mm
        finned length (B)1,985 mm
        Water content0.8 l
        Weight4.2 kg

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq1.30E+015.43E-017.78E-011.44E+011.22E+003.99E-016.95E-021.94E-023.11E-011.07E+000.00E+002.25E-029.40E-011.16E-02-8.25E+00
        GWP - fossil
        Climate change - fossil
        kg CO2 eq1.30E+015.42E-011.01E+001.45E+011.22E+001.41E-016.79E-021.53E-023.08E-011.07E+000.00E+002.25E-029.40E-011.15E-02-8.17E+00
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq0.00E+000.00E+00-2.31E-01-2.31E-012.68E-042.58E-013.43E-043.16E-051.07E-036.41E-040.00E+007.56E-068.25E-053.27E-05-1.35E-02
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq6.26E-022.63E-046.26E-046.35E-023.49E-049.71E-051.30E-034.11E-031.83E-031.26E-030.00E+001.10E-055.76E-058.40E-06-4.49E-02
        ODP
        Ozone Depletion
        kg CFC-11 eq4.93E-071.23E-084.92E-095.10E-072.33E-081.42E-092.28E-095.26E-106.83E-095.45E-080.00E+005.10E-101.69E-082.73E-10-2.09E-07
        AP
        Acidification
        mol H+ eq1.86E-011.35E-037.24E-031.94E-014.53E-035.95E-043.76E-041.18E-041.23E-022.72E-030.00E+005.56E-053.00E-048.21E-05-1.28E-01
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq1.56E-023.98E-051.20E-031.68E-025.41E-054.45E-055.37E-055.22E-069.71E-041.06E-040.00E+001.66E-061.52E-053.03E-06-1.07E-02
        EP - marine
        Eutrophication aquatic marine
        kg P eq3.53E-023.69E-041.07E-033.68E-021.63E-031.35E-047.98E-052.68E-052.62E-037.56E-040.00E+001.52E-051.03E-043.08E-05-1.07E-02
        EP - country
        Eutrophication terrestrial
        mol N eq2.00E-013.79E-039.45E-032.13E-011.73E-021.24E-036.52E-041.76E-049.78E-038.60E-030.00E+001.56E-041.04E-033.30E-04-1.27E-01
        POCP
        Photochemical ozone formation
        kg NMVOC7.49E-022.20E-032.79E-037.99E-026.48E-035.22E-042.00E-046.95E-052.86E-032.50E-030.00E+009.09E-052.90E-041.11E-04-5.07E-02
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq1.82E-031.51E-068.01E-071.82E-031.82E-065.56E-072.79E-071.62E-071.58E-042.56E-060.00E+006.29E-082.79E-072.35E-08-1.31E-03
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ1.68E+028.22E+001.14E+011.88E+021.73E+012.97E+001.46E+002.02E-013.99E+002.78E+010.00E+003.42E-014.41E-012.51E-01-1.00E+02
        WDP
        Water use
        m³ depriv.4.06E+003.91E-021.37E-014.24E+005.72E-027.10E-022.94E-026.02E-031.65E-014.49E-020.00E+001.63E-032.97E-021.06E-02-1.85E+00
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq1.31E+015.44E-011.01E+001.46E+011.22E+001.42E-016.98E-021.95E-023.11E-011.07E+000.00E+002.26E-029.40E-011.16E-02-8.25E+00
        PM
        Particulate Matter emissions
        disease inc.1.15E-065.34E-081.79E-081.22E-066.52E-081.08E-082.09E-091.25E-093.81E-081.73E-080.00E+002.23E-092.51E-091.77E-09-6.68E-07
        IR
        Ionizing radiation, human health
        kBq U-235 eq1.55E+001.03E-023.67E-021.60E+001.44E-026.98E-033.50E-025.68E-047.48E-029.55E-010.00E+004.30E-044.03E-033.30E-04-6.72E-01
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe2.92E+023.96E+003.08E+002.99E+028.37E+001.09E+004.26E-014.30E-012.44E+011.79E+000.00E+001.64E-017.21E+001.10E-01-1.42E+02
        HTP - C
        Human toxicity, cancer effects
        CTUh7.83E-082.40E-103.55E-107.89E-083.33E-101.37E-092.96E-111.04E-112.66E-092.84E-100.00E+001.00E-111.44E-106.45E-12-4.53E-08
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh1.95E-065.88E-091.43E-081.97E-061.30E-086.41E-097.37E-102.58E-101.57E-076.41E-090.00E+002.44E-101.48E-097.25E-11-1.39E-06
        SQP
        Land use related impacts/Soil quality
        -8.93E+018.30E+003.14E+011.29E+029.75E+003.09E-013.99E-012.48E-015.76E+001.20E+010.00E+003.47E-011.28E-015.72E-01-4.26E+01

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ2.97E+011.20E-016.41E+003.63E+011.64E-019.78E-023.18E-015.14E-029.82E-016.22E+000.00E+004.99E-035.03E-024.30E-03-1.61E+01
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ2.97E+011.20E-016.41E+003.63E+011.64E-019.78E-023.18E-015.14E-029.82E-016.22E+000.00E+004.99E-035.03E-024.30E-03-1.61E+01
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ1.68E+028.22E+001.14E+011.88E+021.73E+012.97E+001.46E+002.05E-013.99E+002.78E+010.00E+003.42E-014.41E-012.51E-01-1.00E+02
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ1.68E+028.22E+001.14E+011.88E+021.73E+012.97E+001.46E+002.05E-013.99E+002.78E+010.00E+003.42E-014.41E-012.51E-01-1.00E+02
        SM
        Secondary material
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³1.48E-011.63E-033.88E-031.54E-012.44E-033.47E-031.15E-032.51E-049.63E-036.95E-030.00E+006.79E-057.33E-042.75E-04-6.37E-02

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg0.00E+000.00E+001.02E+001.02E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+003.12E+000.00E+000.00E+00
        MER
        Materials for energy recovery
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+003.72E-010.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00