  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
      • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Katherm HK
          • Katherm QK
          • Katherm QK nano
          • Katherm NK
          • Katherm QL
          • Katherm ID
          • Katherm QE
        • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • TIP
          • TOP
          • Ultra
          • Ultra Allround
          • TOP C
          • Site heater
          • Ultra DX
          • Resistent
        • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Venkon
          • KaCool D AF
          • Ultra
          • KaDius
          • Ultra Allround
          • KaDeck
          • PowerKon LT
          • Venkon XL
          • KaCool W
          • Venkon DX
          • KaCool D HY
          • KaCool D HC
        • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
          • PowerKon LT
        • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Slot diffusers
          • Round/oval duct diffusers
          • Combination diffusers
          • Swirl diffusers
          • Displacement diffusers
          • Industrial diffusers
        • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • KaCompact KG
        • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • UniLine
          • Cassette UniLine
          • Tandem
          • UniLine DX
          • Tandem - Cassette Version
          • Tandem DX
          • ProtecTor
        • Perimeter Heating
        • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • WZA
          • UZS
        • Heat pumps and chillers
        • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Optiline
          • Wooden grilles
      • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Download Centre
        • Calculation programs
        • Hall Heating Tool
        • Air Volume Flow Calculator
      • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Customer Service
        • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Consultation
          • Design
          • Site Measurement
          • Construction including Tailored Solutions
          • Delivery
          • Installation
      • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
        • The Kampmann Group
        • Research and Development
        • Sustainability and Quality
        • Compliance
      • Career
      • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
        • News
        • Technology and Knowledge
        • Interviews
      • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
        • Find Contact
        • Contact Form
      • Home
      • Products
      • Fan Coils
      • Venkon
      • 14861DUR230E00M

      Products

      • Trench Technology
      • Unit Heaters
      • Fan Coils
      • Heat pump-based heater
      • Diffusers
      • Air Handling Units
      • Door Air Curtains
      • Perimeter Heating
      • Decentralised Ventilation Units
      • Heat pumps and chillers

      Company

      • The Kampmann Group
      • Research and Development
      • Sustainability
      • Magazine

      Service

      • Project Support
      • Customer Service
      • Contact

      Career

      • Career with Kampmann

      Contact

      +49 591 7108-8020info@kampmanngroup.com
      • Imprint
      • Kampmann Group - General Terms and Conditions
      • Kampmann Group - General Terms and Conditions of purchase
      • Central Data Protection Instruction
      • Cookies
      • Reporting system
      • Modern Slavery Statement
      • Compliance

      Our products are intended exclusively for B2B sales.

      Venkon

      Article no.: 14861DUR230E00M
      1,415.00 EUR
      no VAT.
      • Details
      • Description
      • Technical data
      • Acoustic data
      • EPD
      • Dimensions
      • Accessories
      • BIM
      • Downloads

      basic unit

      Kampmann Venkon fan coil for heating and/or cooling. Designed for rooms with high demands in terms of low noise emission and cosy room comfort. Hygiene-certified in line with VDI 6022.
      Ceiling unit (also suitable for wall mounting for dry cooling and also for heating). Basic unit made of sendzimir galvanised sheet steel, insulated with a vapour diffusion and noise-reducing layer to prevent the ingress of condensation.
      Insulation thicknessmm3
      Air inletISO Coarse filter
      Optional primary air connection for the introduction of preconditioned air.
      Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.1.73E+02. Further calculations possible online.

      Heat exchanger

      High-output heat exchanger made of round copper pipes with aluminium fins, including anti-twist mechanism. Integrated air vent option.
      System2-pipe
      Max. operating pressurebar10
      Max. entering water temperature°C90
      Min. entering water temperature°C4
      Max. air inlet temp.°C40
      Max. glycol volume%50

      Condensate tray

      Powder-coated galvanised sheet steel condensate tray. Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022.

      Fan

      Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired. Motor fault: automatic motor shut-down in the event of a fault. No fault alarm is possible.
      Insulation class F
      Protection class IP34

      Control

      Electromechanical control version.
      Factory-fitted and wired electrical connection unit in the unit with connection options for on-site signals to control the fan speed and actuators.

      Configuration

      System2-pipe
      Air inletbottom
      Model size63
      Lengthmm925
      Widthmm494
      Heightmm223
      Weightkg24.2
      Water connectionsright
      Connection1/2 inch

      Information on the Venkon

      • Stepless EC fans
      • Quality Made in Germany
      • Extremely low noise in low operating stages and high power in high speed ranges thanks to progressive power characteristic curve
      • Multiple variations in length and appearance
      • Various control options and valve & sheet steel accessories can be factory-fitted and wired
      • Extremely easy to maintain and clean

      Housing structure

      • Housing made entirely of sendzimir galvanised and electrolytically galvanized sheet steel, 1–1.25 mm thick
      • Interior thermally and acoustically insulated with 3 mm thick closed-cell insulation
      • Casing is fully powder-coated and available in all RAL colors

      High-output heat exchanger

      • Copper-aluminum
      • Optimized air and water-side flow for maximum heat and cold dissipation

      Electromechanical control

      • wired ready for connection
      • easily accessible for maintenance due to removable cover
      • Mounting via Velcro strips for easy removal and handling on site

      EC fan

      • Particularly quiet operation at low speeds and high performance at high speeds
      • Low power consumption due to efficient EC technology
      • Vibration-insulated motor fixing on both sides
      • incl. integrated soft start, overvoltage and undervoltage detection and overtemperature protection

      Connection

      • With anti-twist protection to prevent damage to the convectors when screwing in the valves
      • Various valve kits (optional) permanently mounted on the unit and pressurized on the water side
      • Actuators (optional) permanently connected and wired to the valve kit

      Condensate tray

      • Can be easily and conveniently removed for maintenance / cleaning

      Filter

      • Maintenance-friendly filter removal in any installation position
      • Filter washable and therefore reusable

      View

      • Ifront view (ceiling-mounted model)
      • IIview from below (ceiling version)
      • IIIside view (ceiling model)
      • IVside view (wall model)
      • Vside view (wall model)

      Further Information

      • 1there is no need for EC1M control with electromechanical or external control version
      • 2Filter ePM10>50% (M5) or filter ePM1>50% (F7)

      Specifications

      System2-pipe
      Filter classISO Coarse filter
      Basic unit width (A)925 mm
      Spacing of suspension points (B)860 mm
      Rear wall (C)890 mm
      Air discharge opening (D)731 mm
      Weight24.2 kg
      Connection1/2 inch

      We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

      Basic data

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      GWP - Total
      Climate change - total
      kg CO2 eq1.71E+023.99E+00-1.92E+001.73E+023.88E+005.73E-015.63E-020.00E+002.56E+004.16E+010.00E+001.38E-016.35E+005.28E-02-6.70E+01
      GWP - fossil
      Climate change - fossil
      kg CO2 eq1.66E+023.98E+003.26E+001.74E+023.87E+005.70E-015.90E-020.00E+002.54E+003.76E+010.00E+001.37E-016.29E+004.94E-02-6.61E+01
      GWP - Biogenic
      Climate change - biogenic
      kg CO2 eq3.33E+003.08E-03-5.21E+00-1.87E+001.49E-032.91E-03-5.07E-030.00E+009.34E-033.89E+000.00E+001.10E-046.72E-023.42E-03-1.30E-01
      GWP - Luluc
      Climate change - land use and land use change
      kg CO2 eq1.18E+001.88E-032.88E-021.21E+008.34E-043.92E-042.40E-030.00E+007.25E-036.24E-020.00E+006.70E-052.05E-052.35E-05-7.67E-01
      ODP
      Ozone Depletion
      kg CFC-11 eq3.33E-068.93E-085.94E-083.48E-066.93E-085.71E-092.95E-090.00E+004.16E-083.46E-070.00E+003.12E-094.53E-091.39E-09-1.78E-06
      AP
      Acidification
      mol H+ eq1.82E+001.02E-021.24E-021.84E+001.60E-022.39E-032.87E-040.00E+006.11E-028.22E-020.00E+003.40E-048.56E-043.48E-04-1.01E+00
      EP - Freshwater
      Eutrophication aquatic freshwater
      kg P eq1.48E-012.85E-043.27E-031.52E-011.32E-041.79E-045.19E-050.00E+004.79E-035.46E-020.00E+001.01E-051.14E-055.05E-06-8.37E-02
      EP - Marine
      Eutrophication aquatic marine
      kg P eq1.97E-012.88E-035.60E-032.06E-016.10E-035.43E-048.65E-050.00E+004.52E-032.69E-020.00E+009.27E-054.24E-041.36E-04-8.36E-02
      EP - Terrestrial
      Eutrophication terrestrial
      mol N eq2.13E+002.97E-023.82E-022.20E+006.52E-024.99E-036.22E-040.00E+005.46E-021.95E-010.00E+009.51E-044.45E-031.47E-03-9.64E-01
      POCP
      Photochemical ozone formation
      kg NMVOC7.71E-011.65E-021.23E-028.00E-012.24E-022.11E-031.75E-040.00E+001.70E-025.42E-020.00E+005.55E-041.20E-035.18E-04-3.71E-01
      ADPE
      Depletion of abiotic resources - minerals and metals
      kg Sb eq2.01E+011.07E-058.82E-062.01E+014.03E-062.24E-064.01E-070.00E+007.44E-046.32E-050.00E+003.84E-071.22E-071.35E-07-9.43E-03
      ADPF
      Abiotic resource depletion - fossil fuels
      MJ2.19E+036.01E+015.06E+012.30E+035.36E+011.20E+019.38E-010.00E+004.26E+015.68E+020.00E+002.09E+003.79E-011.15E+00-8.82E+02
      WDP
      Water use
      m³ depriv.3.22E+012.81E-017.72E-013.32E+011.47E-012.87E-013.53E-020.00E+001.29E+001.39E+000.00E+009.96E-031.76E-023.39E-02-1.39E+01
      GWP-GHG
      Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
      kg CO2 eq1.69E+023.99E+003.42E+001.76E+023.88E+005.73E-016.19E-020.00E+002.56E+003.82E+010.00E+001.38E-016.29E+004.96E-02-6.70E+01
      PM
      Particulate Matter emissions
      disease inc.1.33E-053.80E-072.16E-071.39E-051.46E-074.37E-082.69E-090.00E+002.18E-073.65E-070.00E+001.36E-086.84E-097.58E-09-5.47E-06
      IR
      Ionizing radiation, human health
      kBq U-235 eq2.00E+017.40E-026.05E-012.07E+013.60E-022.82E-028.88E-030.00E+002.44E-019.03E+000.00E+002.63E-031.60E-034.33E-03-9.71E+00
      HTP - C
      Human toxicity, cancer effects
      CTUh6.22E-071.72E-091.47E-096.25E-078.28E-105.51E-093.27E-110.00E+001.29E-088.13E-090.00E+006.11E-118.61E-109.52E-09-3.24E-07
      HTP - NC
      Human toxicity, non-cancer effects
      CTUh1.63E-054.32E-082.72E-081.63E-054.15E-082.58E-087.49E-100.00E+007.39E-072.51E-070.00E+001.49E-095.60E-096.51E-07-1.06E-05
      SQP
      Land use related impacts/Soil quality
      -8.08E+025.91E+016.21E+021.49E+032.10E+011.24E+004.95E-010.00E+002.22E+018.08E+010.00E+002.12E+001.35E-012.47E+00-3.05E+02

      Resource use

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      PERE
      Use of renewable primary energy excluding resources used as raw materials
      MJ4.37E+028.58E-011.21E+025.59E+024.03E-013.94E-012.73E-010.00E+004.39E+001.14E+020.00E+003.05E-022.30E-028.81E-02-2.31E+02
      PERM
      Use of renewable primary energy resources used as raw materials
      MJ4.73E-010.00E+000.00E+004.73E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PERT
      Total use of renewable primary energy
      MJ4.38E+028.58E-011.21E+025.59E+024.03E-013.94E-012.73E-010.00E+004.39E+001.14E+020.00E+003.05E-022.30E-028.81E-02-2.31E+02
      PENRE
      Use of non-renewable primary energy excluding resources used as raw materials
      MJ2.21E+036.01E+015.06E+012.32E+035.36E+011.20E+019.43E-010.00E+004.26E+015.68E+020.00E+002.09E+003.79E-011.16E+00-8.82E+02
      PENRM
      Use of non-renewable primary energy resources used as raw materials
      MJ4.12E+000.00E+000.00E+004.12E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      PENRT
      Total use of non-renewable primary energy
      MJ2.21E+036.01E+015.06E+012.32E+035.36E+011.20E+019.43E-010.00E+004.26E+015.68E+020.00E+002.09E+003.79E-011.16E+00-8.82E+02
      SM
      Secondary material
      kg2.15E-010.00E+000.00E+002.15E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RSF
      Renewable secondary fuels
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NRSF
      Non-renewable secondary fuels
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      FW
      Net use of fresh water
      m³1.68E+001.77E-025.17E-021.75E+006.38E-031.14E-021.78E-030.00E+004.90E-022.17E-010.00E+004.15E-042.98E-031.27E-03-4.91E-01

      Waste & Output Flows

      Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
      HWD
      Hazardous waste disposed
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      NHWD
      Non-hazardous waste disposed
      kg0.00E+000.00E+005.84E+005.84E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      RWD
      Radioactive waste disposed
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      CRU
      Components for reuse
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      MFR
      Material for recycling
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.83E+010.00E+000.00E+00
      MER
      Materials for energy recovery
      kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+002.54E+000.00E+000.00E+00
      EE (Electrical)
      Exported energy electrical
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
      EE (Thermal)
      Exported energy thermal
      MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00