• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan Coils
        • Venkon XL
        • 34821W0R445EM1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Venkon XL

        Article no.: 34821W0R445EM1
        4,376.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Accessories
        • BIM
        • Downloads

        Radial fan

        • Directly driven radial fan with forward curved impellers in stepless EC design

        High-output heat exchanger

        • made of proven copper/aluminum combination
        • Optimized for maximum power output

        Condensate tray

        • Can be easily and conveniently removed for maintenance/cleaning
        • Optionally available: valve condensate tray that can be mounted on the side of the unit

        Connection unit for circular pipe

        • Optionally mounted ex works
        • High flexibility due to variable number of spigots

        No technical drawing found for 509569

        Basic unit

        Kampmann Venkon XL fan coil for cooling and/or heating. Designed for recirculation air applications with particularly high cooling and external pressure requirements. Designed as a recirculating air version with rectangular duct connection on the intake and discharge side. Hygiene-certified in line with VDI 6022. Sendzimir galvanised sheet steel housing. Wall-mounted unit (also suitable for ceiling mounting)
        Filter classFilter ePM10>50% (M5).
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.3,29E+02. Further calculations possible online.

        Heat exchanger

        High-efficiency heat exchanger made of round copper tubes with aluminium fins, including anti-torsion device to prevent damage to the coil.
        System4-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C90
        Min. entering water temperature°C5
        Max. air inlet temp.°C25
        Max. glycol volume%50

        Condensate tray

        Condensate tray, galvanised sheet steel, powder-coated and glued on all sides with thick insulation. Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022.
        Insulation thicknessmm3

        Fan

        Double-sided suction radial fan. Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired. Integrated motor protection. Insulation class F.

        Control

        • Built-in KaControl MC controller for continuous fan control with motor monitoring.
        • For the control of 24 V DC actuators (Open/Closed) for heating and cooling operation.
        • With connection option for 5 multifunctional inputs (room temperature, window contact, supply and return temperature, heating/cooling changeover, condensate alarm, sequential control via a 0-10 V signal etc.), unit-specific control and regulation algorithms with the core functions of room temperature control (heating/cooling).
        • Timer program with battery-backed real-time clock for four operating modes (Day/Eco/Extra/Off), commissioning function.
        • Grouping of up to 10 units and a display to create a control zone using CAN-bus, automatic addressing and communication monitoring of all bus subscribers, continuous synchronisation of all statuses and parameters within the group.
        • CAN bus interface and galvanically isolated RS485 interface, each with two terminal blocks for separate connection with daisy chain cabling with a switchable terminal resistor.
        • connection of central functions, such as heating cooling changeover to a freely selectable unit within the group.
        • Ethernet interface with two RJ45 sockets with built-in switching function.
        • KNX-TP interface with socket terminal, all terminals are designed as plugs, wireless communication via Wi-Fi web server for user-friendly operation and for complete password-protected parametrisation.
        • protocols can be unlocked via licences: BACnet/IP, Modbus TCP, Modbus RTU, KNX.

        Connection

        includes factory-fitted adapters to 3/4 inch R-thread Female NPT thread cooling
        Connection Cooling3/4''
        Female NPT thread heating
        Connection Heating3/4''

        Configuration

        System4-pipe
        Water connectionsright
        Nominal voltageV230
        Model size4
        Lengthmm262
        Widthmm1836
        Heightmm650
        Weightkg70.5

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq3.24E+025.33E+00-2.76E-013.29E+021.09E+016.81E+006.39E-020.00E+004.92E+007.84E+010.00E+006.80E-012.80E+006.65E-01-1.38E+02
        GWP - fossil
        Climate change - fossil
        kg CO2 eq3.20E+025.32E+005.22E+003.31E+021.09E+011.31E+006.13E-020.00E+004.91E+007.84E+010.00E+006.80E-012.80E+005.76E-01-1.37E+02
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq6.35E-018.94E-04-5.50E+00-4.87E+002.02E-035.50E+000.00E+000.00E+000.00E+000.00E+000.00E+001.26E-041.35E-048.80E-02-8.72E-02
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq2.39E+002.46E-037.44E-032.40E+004.54E-036.30E-042.56E-030.00E+009.25E-033.93E-020.00E+002.84E-041.41E-051.60E-04-1.07E+00
        ODP
        Ozone Depletion
        kg CFC-11 eq4.83E-068.41E-085.20E-084.96E-061.75E-071.69E-089.95E-100.00E+001.29E-075.11E-070.00E+001.09E-087.15E-104.56E-09-8.25E-07
        AP
        Acidification
        mol H+ eq4.82E+008.20E-021.29E-024.92E+002.77E-025.18E-033.05E-040.00E+007.31E-022.19E-010.00E+001.73E-034.25E-041.27E-03-1.33E+00
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq2.85E-023.51E-052.88E-042.88E-021.02E-044.24E-054.20E-060.00E+005.81E-045.26E-030.00E+006.40E-065.84E-072.80E-06-4.65E-03
        EP - marine
        Eutrophication aquatic marine
        kg P eq8.07E-012.04E-022.86E-038.30E-016.87E-031.11E-037.91E-050.00E+002.82E-023.37E-020.00E+004.30E-041.90E-045.85E-04-1.28E-01
        EP - country
        Eutrophication terrestrial
        mol N eq4.74E+002.27E-013.28E-025.00E+007.62E-021.18E-026.19E-040.00E+008.25E-023.86E-010.00E+004.76E-032.06E-035.07E-03-1.51E+00
        POCP
        Photochemical ozone formation
        kg NMVOC1.62E+006.70E-021.47E-021.70E+004.20E-024.83E-032.00E-040.00E+002.87E-021.54E-010.00E+002.62E-035.20E-041.82E-03-5.39E-01
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq5.55E-021.03E-056.72E-065.55E-023.07E-057.65E-064.17E-070.00E+001.16E-031.04E-040.00E+001.92E-061.08E-074.19E-07-5.81E-03
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ4.37E+037.29E+019.87E+014.54E+031.64E+022.01E+011.06E+000.00E+007.42E+011.45E+030.00E+001.02E+013.92E-014.00E+00-1.28E+03
        WDP
        Water use
        m³ depriv.-1.22E+022.82E-017.75E-01-1.21E+028.36E-01-9.92E-023.80E-020.00E+001.75E+001.70E+010.00E+005.23E-026.96E-02-1.09E+00-3.57E+01
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq3.24E+025.34E+005.23E+003.34E+021.09E+011.47E+006.40E-020.00E+004.93E+007.85E+010.00E+006.82E-012.80E+005.91E-01-1.38E+02
        PM
        Particulate Matter emissions
        disease inc.2.38E-053.46E-071.73E-072.43E-051.06E-068.93E-082.76E-090.00E+003.37E-071.02E-060.00E+006.65E-082.25E-092.65E-08-1.67E-05
        IR
        Ionizing radiation, human health
        kBq U-235 eq5.60E+022.08E-027.14E-015.61E+025.62E-021.77E-025.25E-030.00E+006.09E-011.24E+010.00E+003.52E-032.82E-041.94E-03-8.03E-01
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe8.19E+031.53E+011.17E+018.21E+033.93E+012.32E+015.52E-010.00E+002.18E+021.83E+020.00E+002.46E+004.15E+005.52E+02-2.51E+03
        HTP - C
        Human toxicity, cancer effects
        CTUh4.81E-062.57E-087.58E-094.85E-065.59E-085.11E-082.31E-100.00E+009.08E-081.26E-070.00E+003.49E-094.46E-101.53E-09-5.84E-06
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh4.00E-053.42E-082.24E-084.01E-051.05E-071.05E-085.21E-100.00E+006.15E-073.79E-070.00E+006.54E-094.66E-093.95E-08-6.55E-06
        SQP
        Land use related impacts/Soil quality
        -2.10E+034.43E+016.34E+022.77E+031.65E+025.94E+006.07E-010.00E+005.41E+012.09E+020.00E+001.03E+011.25E-018.15E+001.12E+02

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ8.79E+027.77E-011.01E+029.82E+022.08E+001.09E+002.23E-010.00E+007.96E+001.56E+020.00E+001.30E-011.57E-026.91E-02-5.89E+02
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ3.25E+000.00E+004.25E+014.58E+010.00E+00-4.25E+010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00-3.25E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ8.83E+027.77E-011.44E+021.03E+032.08E+00-4.15E+012.23E-010.00E+007.96E+001.56E+020.00E+001.30E-01-3.24E+006.91E-02-5.89E+02
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ4.37E+037.29E+019.87E+014.54E+031.64E+022.01E+011.06E+000.00E+007.42E+011.45E+030.00E+001.02E+013.92E-014.00E+00-1.28E+03
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ4.37E+037.29E+019.87E+014.54E+031.64E+022.01E+011.06E+000.00E+007.42E+011.45E+030.00E+001.02E+013.92E-014.00E+00-1.28E+03
        SM
        Secondary material
        kg7.74E+000.00E+000.00E+007.74E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³-1.18E+022.83E-017.64E-01-1.17E+028.40E-01-8.24E-023.75E-020.00E+001.77E+001.65E+010.00E+005.25E-026.91E-02-1.09E+00-1.83E+01

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg0.00E+000.00E+004.96E+004.96E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg0.00E+000.00E+009.84E+009.84E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+004.42E+010.00E+000.00E+00
        MER
        Materials for energy recovery
        kg0.00E+000.00E+000.00E+000.00E+000.00E+003.20E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.04E+000.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.88E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+006.45E+00