• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan Coils
        • KaDeck
        • 326126461111M1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        KaDeck

        Article no.: 326126461111M1
        3,689.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • BIM
        • Downloads

        Basic unit

        Kampmann KaDeck fan coil for high-quality air conditioning in new and existing buildings. Ultra-low-height basic unit. Intended for installation in suspended ceilings. All components are accommodated within the housing and can be accessed without a tool. The housing consists of an insulating and heat-bridge-free EPP (expanded polypropylene) design, which minimises heat exchange into the false ceiling, is sound-insulating and simplifies installation on account of its low overall weight. Within the unit, the organic forms and the absence of corners and edges facilitate the cleaning of all surfaces. The visible design panel is made of RAL 9016 traffic white powder-coated sheet steel.
        The installation brackets supplied enable the housing supports to be pre-installed and the KaDeck subsequently fitted. Then the installation brackets are screwed to the KaDeck. The optimised discharge fins discharge the air horizontally along the ceiling to use the Coanda effect. A service hatch is not needed on site as accessories, such as valves, are also installed within the housing. The special utility model-protected motor cooling doubles the service life of the fans (to min. 40,000 operating hours also at 75°C water temperature in heating mode). Primary air can be introduced into the air intake of the unit on two sides of the housing through optional connection spigots. The room air is cleaned by a COARSE air filter. Hygiene-certified in line with VDI 6022.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.1,32E+02. Further calculations possible online.

        Heat exchanger

        High-output heat exchanger, consisting of round copper tubes with aluminium fins, suitable for use with LPHW.
        System4-pipe
        Max. operating pressurebar16
        Max. entering water temperature°C75
        Min. entering water temperature°C6
        Max. air inlet temp.°C35
        Max. glycol volume%50

        Condensate tray

        Condensate tray designed as an independent component that can be removed for cleaning and maintenance in accordance with VDI 6022. Speed-controlled condensate pump with dynamic adaptation of the delivery rate and minimum operating noise, with sound-absorbent EEP insulated housing. Capacitive float switch for reduced maintenance.

        Fan

        Tangential fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired.
        Protection class IP44

        Control

        • Built-in KaControl MC controller for continuous fan control with motor monitoring.
        • For the control of 24 V DC actuators (Open/Closed) for heating and cooling operation.
        • With connection option for 5 multifunctional inputs (room temperature, window contact, supply and return temperature, heating/cooling changeover, condensate alarm, sequential control via a 0-10 V signal etc.), unit-specific control and regulation algorithms with the core functions of room temperature control (heating/cooling).
        • Timer program with battery-backed real-time clock for four operating modes (Day/Eco/Extra/Off), commissioning function.
        • Grouping of up to 10 units and a display to create a control zone using CAN-bus, automatic addressing and communication monitoring of all bus subscribers, continuous synchronisation of all statuses and parameters within the group.
        • CAN bus interface and galvanically isolated RS485 interface, each with two terminal blocks for separate connection with daisy chain cabling with a switchable terminal resistor.
        • connection of central functions, such as heating cooling changeover to a freely selectable unit within the group.
        • Ethernet interface with two RJ45 sockets with built-in switching function.
        • KNX-TP interface with socket terminal, all terminals are designed as plugs, wireless communication via Wi-Fi web server for user-friendly operation and for complete password-protected parametrisation.
        • protocols can be unlocked via licences: BACnet/IP, Modbus TCP, Modbus RTU, KNX.
        • Built-in 24 V DC current measurement.

        Configuration

        Cooling typewet cooling
        Ceiling finishSuspended ceiling
        Air outletone-sided air outlet
        System4-pipe
        Ceiling grid dimensions625 x 625 mm
        Filter classISO Coarse filter
        Widthmm620
        Heightmm165
        Lengthmm1240
        Weightkg22.6
        Connection1/2 inch

        Space-saving heating and cooling

        • For use with low suspended ceilings with an appliance height of 165 mm
        • Particularly light thanks to the EPP housing (expanded polypropylene)
        • No service hatches necessary: all relevant maintenance components are located in the unit
        • fulfills the requirements of VDI 6022

        Sheet steel and EPP hybrid housing

        • Rigidity and strength thanks to galvanized sheet steel frame
        • Thermal and acoustic isolation thanks to thermal bridge-free foamed EPP body
        • Organic interior shapes for easy cleaning

        Connection frame and ceiling panel

        • Optionally suitable for 600x600 mm or 625x625 mm ceiling grid
        • Ceiling panel and frame in RAL 9016 (traffic white), color selection according to customer requirements possible
        • Ceiling panel can be opened without tools, hinges and locks in industrial quality for an extremely long service life
        • Internal cleanable ISO Coarse air filter for dust protection of the internal components

        ease of installation and maintenance

        • Ceiling panel and condensate tray can be opened without tools
        • No service hatches required on site
        • All components can be reached after removing the condensate tray
        • Easy cleaning of all air-conducting surfaces possible
        • Valve installation (adjustable 2-way or differential pressure independent) inside the housing

        connection and operational safety

        • Device design and component selection optimized for easy installation and operation
        • Reduction of the total weight of the device to 60% compared to a sheet steel construction for back-friendly installation on the ceiling
        • Connection areas in the EPP with flow and return, primary air labeled

        Heat exchanger

        • High-efficiency heat exchanger with copper tubes and aluminum fins
        • Suitable for LPHW heating systems

        Condensate drain

        • includes humid cooling configuration in the scope of delivery
        • Compact design, without separate float, prevents possible leaks at connections
        • Extremely smooth-running pump, speed and flow rate adapt to the condensate level in the pump sump
        • the condensate level is determined via a capacitive sensor, preventing the float switch from sticking
        • Alarm contact in the event of malfunction or excessive water level in the condensate tray

        Condensate tray

        • Condensate tray can be removed without tools for cleaning and maintenance
        • for thermal and acoustic isolation consisting of EPP
        • Condensate-bearing area made of ABS plastic, suitable for disinfectants
        • Gradient on all sides for fast and complete condensate removal from the air-bearing area

        durable EC tangential fan

        • Noise-optimized, quiet-running 3-speed, stepless and energy-saving EC motor
        • Horizontal cross-flow roller, aerodynamically optimized EPP/aluminium contour in CFD
        • Patent-protected bypass motor cooling against heat build-up in heating mode to increase motor service life by 40%

        Primary air supply

        • Two spigots can each be connected at the head end
        • Easy removal of the EPP closures
        • Primary air is routed via the heat exchanger for temperature control

        • IView from below
        • IIFront view
        • IIIside view
        • IVisometric view

        System4-pipe
        Ceiling grid dimensions625 x 625 mm
        Length (A)1,240 mm
        Width (B)620 mm
        heating water content0.2 l
        cooling water content0.8 l
        Weight22.6 kg

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq1.22E+022.57E+007.93E+001.32E+024.10E+002.65E+005.63E-022.81E-022.80E+009.28E+000.00E+001.16E-014.29E+003.71E-02-3.69E+01
        GWP - fossil
        Climate change - fossil
        kg CO2 eq1.18E+022.57E+008.24E+001.29E+024.10E+002.54E+005.90E-022.27E-022.73E+008.43E+000.00E+001.16E-014.25E+003.52E-02-3.65E+01
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq2.66E+002.00E-03-3.63E-012.30E+001.42E-031.09E-01-5.07E-03-5.70E-034.48E-028.32E-010.00E+009.26E-054.19E-021.91E-03-3.18E-01
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq6.64E-011.22E-034.85E-027.14E-017.78E-042.51E-032.40E-031.11E-022.43E-021.41E-020.00E+005.66E-051.87E-051.78E-05-4.05E-02
        ODP
        Ozone Depletion
        kg CFC-11 eq2.42E-065.77E-082.23E-072.70E-067.15E-083.46E-082.95E-098.54E-105.23E-089.79E-080.00E+002.64E-094.55E-099.95E-10-7.73E-07
        AP
        Acidification
        mol H+ eq1.20E+006.51E-032.16E-021.23E+001.77E-021.10E-022.87E-043.98E-045.38E-022.45E-020.00E+002.87E-045.91E-042.51E-04-5.57E-01
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq9.83E-021.85E-046.25E-031.05E-011.24E-049.78E-045.19E-057.90E-064.27E-031.22E-020.00E+008.57E-068.70E-063.46E-06-5.01E-02
        EP - marine
        Eutrophication aquatic marine
        kg P eq1.35E-011.82E-031.05E-021.47E-016.83E-032.58E-038.65E-055.34E-054.27E-036.35E-030.00E+007.83E-052.96E-049.78E-05-4.91E-02
        EP - country
        Eutrophication terrestrial
        mol N eq1.46E+001.88E-026.50E-021.54E+007.31E-022.36E-026.22E-042.59E-044.97E-024.88E-020.00E+008.04E-043.01E-031.05E-03-5.79E-01
        POCP
        Photochemical ozone formation
        kg NMVOC5.41E-011.05E-022.08E-025.73E-012.45E-029.10E-031.75E-041.16E-041.59E-021.39E-020.00E+004.69E-048.07E-043.71E-04-2.15E-01
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq8.98E-036.97E-061.57E-059.00E-033.58E-061.10E-054.01E-071.72E-075.86E-049.38E-050.00E+003.25E-071.06E-078.58E-08-5.55E-03
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ1.65E+033.88E+011.21E+021.80E+035.63E+013.56E+019.38E-013.29E-013.85E+011.26E+020.00E+001.76E+002.87E-018.35E-01-5.20E+02
        WDP
        Water use
        m³ depriv.2.57E+011.82E-011.48E+002.73E+011.43E-01-2.43E-013.53E-022.20E-027.95E-016.27E-010.00E+008.41E-031.49E-022.74E-02-9.89E+00
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq1.21E+022.57E+008.55E+001.32E+024.11E+002.61E+006.19E-023.39E-022.78E+008.56E+000.00E+001.16E-014.25E+003.53E-02-3.67E+01
        PM
        Particulate Matter emissions
        disease inc.9.04E-062.47E-072.10E-079.50E-061.30E-071.96E-072.69E-091.92E-092.48E-071.21E-070.00E+001.15E-084.59E-095.48E-09-2.49E-06
        IR
        Ionizing radiation, human health
        kBq U-235 eq1.35E+014.79E-021.07E+001.47E+013.42E-021.83E-018.88E-031.90E-033.94E-011.96E+000.00E+002.22E-031.42E-032.53E-03-7.38E+00
        HTP - C
        Human toxicity, cancer effects
        CTUh4.51E-071.11E-092.31E-094.54E-077.87E-101.87E-083.27E-112.00E-111.32E-083.11E-090.00E+005.16E-116.04E-106.16E-09-1.66E-07
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh1.05E-052.78E-084.84E-081.05E-054.38E-088.89E-087.49E-103.58E-106.12E-071.33E-070.00E+001.26E-094.06E-094.21E-07-5.83E-06
        SQP
        Land use related impacts/Soil quality
        -5.71E+023.84E+011.15E+027.25E+021.83E+011.00E+014.95E-015.61E-011.89E+013.10E+010.00E+001.79E+009.95E-021.77E+00-2.08E+02

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ2.75E+025.55E-013.28E+013.08E+023.81E-012.60E+002.73E-011.30E-018.63E+003.64E+010.00E+002.58E-021.97E-025.06E-02-6.66E+01
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ2.75E+025.55E-013.28E+013.08E+023.81E-012.60E+002.73E-011.30E-018.63E+003.64E+010.00E+002.58E-021.97E-025.06E-02-6.66E+01
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ1.65E+033.88E+011.21E+021.80E+035.63E+013.56E+019.43E-013.37E-013.85E+011.26E+020.00E+001.76E+002.87E-018.35E-01-5.20E+02
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ1.65E+033.88E+011.21E+021.80E+035.63E+013.56E+019.43E-013.37E-013.85E+011.26E+020.00E+001.76E+002.87E-018.35E-01-5.20E+02
        SM
        Secondary material
        kg4.36E-010.00E+000.00E+004.36E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³1.40E+007.57E-031.07E-011.51E+001.42E-01-2.47E-013.50E-022.10E-028.21E-015.13E-020.00E+008.39E-031.95E-039.14E-04-1.01E+01

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg0.00E+000.00E+005.24E+005.24E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.41E+020.00E+000.00E+00
        MER
        Materials for energy recovery
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.04E+000.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00