• Global English
  • Projects

Country and Language

  • Germany

    Deutsch
  • France

    Français
  • Netherlands

    Nederlands
  • Switzerland

    DeutschFrançais
  • Austria

    Deutsch
  • Poland

    Polski
  • United Kingdom

    English (United Kingdom)
  • Canada

    English (Canada)Français (Canada)
  • Italy

    Italiano
  • USA

    English (United States)
  • Global

    EnglishРусский
  • Products
  • Tools
  • Service
  • Company
  • Career
  • Magazine
  • Contact
        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Trench Technology
        • Katherm HK
        • Calculation

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        Katherm HK P

        EC tangential fan-assisted convection for heating or cooling with primary air.

        • Heating
        • Cooling
        • Ventilation
        Product image
        Exploded view
        Hero image
        • Overview
        • Variants
        • Calculation & selection
        • Planning information
        • Downloads

        EC tangential fan

        • with powerful, noise-optimized EC fan motor
        • as a continuous fan belt with flow-optimized cross-flow rollers, cascaded by an innovative coupling system
        • Continuous, even flow through the convectors
        • Stepless speed control via 0-10 V signal, motor monitoring with internal fault processing

        Attachment of cross-flow fan

        • Easy removal of the tangential fan without tools
        • Innovative combined coupling/ball stud system
        • Simultaneous sound decoupling

        Connection module

        • includes all building services interfaces on one connection side
        • Simple and time-saving installation
        • With connection and control box, EC fan motor, heat exchanger connection and condensate connection with optional condensate pump

        Connection kit for condensation pump

        • for draining the condensate
        • Provided or factory-fitted; direct wiring in the electrical connection box
        • with quiet condensate pump in compact housing, with connection elbow
        • Plug-in power supply and fault alarm

        Segment plate

        • As simultaneous finger protection for the tangential fan, filter mounting frame, air guide plate, grate support and cross brace for stiffening the duct

        Cover plate

        • as a privacy screen and protection against soiling
        • for connection and extension module
        • secured with screw plugs

        Width, height & length

        Trench convectors can be selected in different lengths (A) depending on the version, so that they can be optimally integrated into common window hinge systems.

        The functional width (B) and height (C) allow individual adaptation to the floor structure and at the same time determine the performance of the trench convectors.

        Continuous hinges can be realized using empty parts, column recesses, angles, etc.

        Width (B)Height (C)Length (A)
        310 mm180 mm830 - 2990 mm

        System

        2-pipe system

        With this design, the entire heat exchanger surface is available for temperature control, depending on the medium currently present in the pipe system (cold or hot water). Switch-over between heating and cooling takes place centrally via the building management system. This variant is particularly suitable for applications with seasonal switch-over and reduced installation effort.

        4-pipe system

        This version is suitable for sophisticated air conditioning concepts in which each room zone or unit can be switched over individually between heating and cooling. By routing the heating and cooling medium separately, the system offers maximum flexibility and comfort - ideal for buildings with changing usage requirements.

        Type of system
        2-pipe
        4-pipe

        Grate start / Grate design

        Various grating variants are available for the cover, which ideally meet both functional and design requirements. Different materials can be selected depending on the application area.

        In addition, different surface coatings and colors are possible in order to achieve a visual adaptation to the building architecture and interior design.

        What is technically relevant is that the choice of material and geometry can influence the free air cross-section and thus have an impact on the performance of the unit. These effects are taken into account in the performance calculation.

        Grille designGrille finishGrille bar spacingFree area, approx.
        Roll-up grilleAluminium, natural anodised12.0 mm70 %
        Roll-up grilleStainless steel10.5 mm65 %

        Control option

        We offer various solutions for the control and regulation of our units, which can be used depending on the application and requirements:

        Electromechanical control

        This variant is ideal for simple applications. All integrated actuators are factory-wired to terminals and can be connected to our electromechanical accessories such as thermostats or external controllers.

        KaControl MC1

        Our comprehensive comfort control offers extended control options for individual rooms or appliance groups. It can be operated either via a touch display or a web interface. Thanks to on-site 0-10 V control or common communication protocols such as Modbus RTU & TCP, BACnet and KNX, this solution is ideal for all BMS applications.

        Control option
        electromechanical 230 V
        KaControl MC1

        heat and cooling outputs

        • The heat and cooling outputs were determined in accordance with DIN EN 16430 (Parts 1-3) under practical conditions based on DIN EN 442.
        • The standard regulates performance measurements in uniform standards, especially for underfloor convectors.
        • Ensuring uniform comparability of different devices
        • Safety in planning and design

        Arrangement of air outlet for cooling / heating

        • directly on the façade, without a large gap (A, B)
        • provide expansion joints (1) on site to prevent compression by, for example, screed
        • Arrangement convector on the window side, tangential fan on the room side
        • effective cooling and heating, especially for large areas of glass
        • rising air forms an air vortex that flows into the room without creating a draft.
        • optimal shielding and uniform temperature control in the room

        Acoustics

        The units are equipped with quiet, sound-optimized EC fans.

        Sound pressure and sound power levels are tabulated in the technical data.

        The actual sound pressure level depends heavily on:

        • the number of units;
        • the acoustic properties of the room.

        Recommendation: The design should always take into account the permissible sound pressure level in the room.

        Primary air supply

        Supply modules positioned below the Katherm HK unit are perfectly suited to supply prepared primary air (fresh air) into a space. It escapes through a discharge slot arranged along the length of the trench convector and mixes with the secondary air heated or cooled by the convector before exiting into the room.

        Properties:

        • mixing with heated or cooled secondary air before exiting into the room
        • low, low-turbulence exit velocity
        • effective shielding in front of window surfaces
        • Heating, cooling and air supply are efficiently combined.

        Features:

        • the variable number of modules is determined by the channel length
        • convenient adjustment of the volume of air supplied due to the variable number of modules and the adjustable slider.
        • pp to 60 m³/h of primary air can be supplied per supply air module.

        Hydraulic connection

        For simplified hydraulic connection of the Katherm HK, various valve kits are available for 2- and 4-pipe connections:

        • pre-adjustable 2-way valve kit
        • Differential pressure-independent valve kit

        consisting of thermostatic valve, return shut-off valve and flexible stainless steel corrugated pipes with pressable copper fitting

        • with matching valve actuators for different control variants

        Hygiene Directive VDI 6022

        • Katherm HK P is compliant with the relevant Hygiene Directive VDI 6022
        • Objective: To ensure a healthy and hygienic supply of fresh air.
        • applies to common rooms such as workplaces, meeting rooms, break rooms, living rooms, sports venues, sales rooms

        The Katherm HK P meets, for example, the following requirements:

        • Air filter above intake area
        • pull-out, easy-to-clean condensate tray
        • Accessibility of all air- and water-carrying components for cleaning

        Life Cycle Assessment Data (LCA)

        • Considers the environmental impact of the product over its entire life cycle.
        • Published as an Environmental Product Declaration (EPD) in accordance with standard EN 15804.
        • Available for download at International EPD System.
        • Item number-specific life cycle assessment data in the technical data sheets.
        • Product is registered in the DGNB Navigator (building product platform).

        Serves as proof for certification systems, e.g:

        • DGNB (German Sustainable Building Council);
        • BREEAM (Building Research Establishment Environmental Assessment Method);
        • LEED (Leadership in Energy and Environmental Design).