        • ProductsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Trench TechnologyArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Katherm HK
            • Katherm QK
            • Katherm QK nano
            • Katherm NK
            • Katherm QL
            • Katherm ID
            • Katherm QE
          • Unit HeatersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • TIP
            • TOP
            • Ultra
            • Ultra Allround
            • TOP C
            • Site heater
            • Ultra DX
            • Resistent
          • Fan CoilsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Venkon
            • KaCool D AF
            • Ultra
            • KaDius
            • Ultra Allround
            • KaDeck
            • PowerKon LT
            • Venkon XL
            • KaCool W
            • Venkon DX
            • KaCool D HY
            • KaCool D HC
          • Heat pump-based heaterArrow Right 1 Streamline Icon: https://streamlinehq.com
            • PowerKon LT
          • DiffusersArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Slot diffusers
            • Round/oval duct diffusers
            • Combination diffusers
            • Swirl diffusers
            • Displacement diffusers
            • Industrial diffusers
          • Air Handling UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • KaCompact KG
          • Door Air CurtainsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • UniLine
            • Cassette UniLine
            • Tandem
            • UniLine DX
            • Tandem - Cassette Version
            • Tandem DX
            • ProtecTor
          • Perimeter Heating
          • Decentralised Ventilation UnitsArrow Right 1 Streamline Icon: https://streamlinehq.com
            • WZA
            • UZS
          • Heat pumps and chillers
          • Design grillesArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Optiline
            • Wooden grilles
        • ToolsArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Download Centre
          • Calculation programs
          • Hall Heating Tool
        • ServiceArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Customer Service
          • Project SupportArrow Right 1 Streamline Icon: https://streamlinehq.com
            • Consultation
            • Design
            • Site Measurement
            • Construction including Tailored Solutions
            • Delivery
            • Installation
        • CompanyArrow Right 1 Streamline Icon: https://streamlinehq.com
          • The Kampmann Group
          • Research and Development
          • Sustainability and Quality
          • Compliance
        • Career
        • MagazineArrow Right 1 Streamline Icon: https://streamlinehq.com
          • News
          • Technology and Knowledge
          • Interviews
        • ContactArrow Right 1 Streamline Icon: https://streamlinehq.com
          • Find Contact
          • Contact Form
        • Home
        • Products
        • Fan Coils
        • KaDius
        • 360001200021C1

        Products

        • Trench Technology
        • Unit Heaters
        • Fan Coils
        • Heat pump-based heater
        • Diffusers
        • Air Handling Units
        • Door Air Curtains
        • Perimeter Heating
        • Decentralised Ventilation Units
        • Heat pumps and chillers

        Company

        • The Kampmann Group
        • Research and Development
        • Sustainability
        • Magazine

        Service

        • Project Support
        • Customer Service
        • Contact

        Career

        • Career with Kampmann

        Contact

        +49 591 7108-8020info@kampmanngroup.com
        • Imprint
        • Kampmann Group - General Terms and Conditions
        • Kampmann Group - General Terms and Conditions of purchase
        • Central Data Protection Instruction
        • Cookies
        • Reporting system
        • Modern Slavery Statement
        • Compliance

        Our products are intended exclusively for B2B sales.

        KaDius

        Article no.: 360001200021C1
        3,274.00 EUR
        no VAT.
        • Details
        • Description
        • Technical data
        • Acoustic data
        • EPD
        • Dimensions
        • Accessories
        • BIM
        • Downloads

        basic unit

        Kampmann KaDius fan coil design ceiling unit with a room unit design that blends into the interior design. Featuring a 360° air outlet, high-end designer spaces are evenly and comfortably heated and cooled.
        As a very shallow under-ceiling unit (208 mm overall height), it can be integrated discreetly into rooms with open ceiling concept or with a low suspended ceiling. Its appearance is not affected, as all components are fitted within the unit. Thanks to the independence of the casing components, the KaDius can be integrated into furnishing elements that blend with the interior design concept.  The housing consists of an insulating and heat-bridge-free EPP (expanded polypropylene) design, which is sound-insulating and simplifies installation on account of its low overall weight. Within the unit, its organic form with no corners and edges enables all surfaces to be cleaned, and provides for an optimised, turbulence-free air flow. The utility mode-protected and patent-pending design provides for installed close to the ceiling with a sealed underside. Two knurled screws can be loosened on the top of the unit for maintenance. The base of the unit is held on the functional unit by additional magnets. The base of the unit can be lowered by 157 mm but dropping it along the retaining rails. Components relevant for maintenance can now be accessed. If required, the base of the unit can also be removed without tools.
        Life Cycle Assessment (LCA) data is published in the form of an EPD according to EN 15804 and is available to download from the International EPD System. Registered in the building products platform DGNB Navigator. GWP (phase A1-A3), kg CO2 Äq.1,34E+02. Further calculations possible online.

        Casing

        The visible design panel and side panels are made of powder-coated sheet steel in RAL 9016 traffic white with a satin finish (standard). Alternative colors can be selected at no additional cost:
        • RAL 9006 white aluminium
        • RAL 9005 matt satin deep black
        • RAL 6005 moss green matt
        • DB 703 iron-glimmer grey matt-satin
        • reddish brown metallic fine structure
        • gold metallic fine structure

        Filter

        ISO Coarse filter on the upper side of the unit protects against accidental intrusion and dirt in the unit. Filters can be removed and regenerated during maintenance to clean them. Cleaning and maintenance are carried out according to VDI 6022. Hygiene-certified in line with VDI 6022.

        Heat exchanger

        High-efficiency heat exchanger with copper tubes and aluminum fins. Integrated air vent option.
        System2-pipe
        Max. operating pressurebar10
        Max. entering water temperature°C75
        Min. entering water temperature°C6
        Max. air inlet temp.°C30
        Max. glycol volume%50

        Condensate tray/pump

        The condensate tray made of EPP with a specially treated surface for safe drainage is integrated into the lower shell of the unit. Speed-controlled condensate pump with dynamic adaptation of the delivery rate and minimum operating noise. Capacitive float switch for reduced maintenance.

        Fan

        Axial fan with safety guard. Energy-saving EC fan with 0-10 V input for continuously variable speed control. All rotating parts have low-noise and maintenance-free bearings. Factory-wired. Overtemperature protection of the fan by active temperature management.
        Protection class IP54
        Insulation class F

        valve

        The internal and factory-fitted valve kit includes:
        • Thermostatic valve to shot off the water flow
        • 2-point actuator
        • Shut-off ball valve for the manual shut-off of the water flow
        • Corrugated pipes with 18 mm copper connection spigots for connection to supply lines
        • Angle section 90 degrees

        Control

        An easily accessible locking repair switch is fitted on the unit.
        An easily accessible electrical junction box is located inside the basic unit. It contains a control PCB with plug-in terminals.
        Connection option for a condensate pump
        potential-free motor malfunction signal contact
        KaControl C1 control system factory fitted and wired.
        Operation via a separate room control unit acting as a master unit or used as a slave unit.
        • Room control for up to six devices via KaController, expandable to up to 30 devices via CANbus interface (CANbus card required)
        • slot for opt. Interfaces: CANbus / Modbus / KNX card
        • Temperature recording by a sensor in the room control unit or air intake sensor
        • One digital input configurable for:
        • Device On/Off
        • Comfort/Economy mode switch
        • Heating/Cooling changeover
        • Window contact, presence detector contact
        • Card reader contact
        • Output for continuous (0-100%) control of the EC fan
        • night mode (energy-saving mode) that can be activated via a timer program in the KaController or digital input
        • room and unit frost protection control
        • 5-stage fan control 1-2-3-4-5
        • Demand-led automatic fan mode with constant (0-100 %) fan control, shut-down in the event of a fault
        • With integrated and configured air intake temperature sensor for optimum detection of the air intake or room temperature

        Packaging and assembly

        A removable drilling template is included in the packaging of the unit, which simplifies the marking of the drilling points. The packaging concept enables the unit to be installed complete with its packaging. After installation, the drilling template is reinserted so that the unit remains protected from dirt until it is commissioned. Using fastening material supplied on site, the KaDius can be mounted on the M4 or M8 blind rivet nuts. It is possible to suspend the KaDius using wire cables (optional accessory).

        Configuration

        Model size1
        Casingfully cased
        Valve version2-way valve, not pre-settable
        Diametermm852
        Heightmm208
        Weightkg25.6
        Water contentl1.8
        Connection3/4''

        For special architecture

        • Integration into modern room concepts
        • Air intake from above for a closed panel
        • Complete unit: All components and accessories are located inside the KaDius.
        • is suitable for use just below a ceiling or freely suspended in the room
        • with 360° outlet for comfortable heating and cooling
        • Particularly light thanks to the EPP housing (expanded polypropylene)
        • fulfills the requirements of VDI 6022
        • Unique maintenance concept by lowering the lower appliance segment

        Expanded polypropylene (EPP) casing

        • Basic unit is based on an innovative and utility model-protected EPP basic structure
        • EPP is characterized by high rigidity, low weight and excellent insulation and recyclability
        • Optimum air flow thanks to the option of complex shaping
        • Organic internal structures for easy cleaning

        Innovative maintenance concept

        • Simple lowering of the lower appliance segment possible
        • To do this, loosen two knurled screws and pull down the lower part held by magnets until it hangs on the guide rail
        • All components are easily accessible to ensure easy cleaning

        Condensate tray with condensate pump

        • Extremely smooth-running and powerful condensate pump with capacitive resistance sensor is pre-assembled
        • Lower appliance segment serves as condensate tray
        • Gradient on all sides to the suction area of the pump for fast and complete condensate removal from the air-bearing area
        • Sophisticated concept for easy maintenance and cleaning

        Axial fan with contact protection

        • Stepless EC axial fan
        • High efficiency and low noise thanks to the aerodynamic design of the blade geometry
        • Overtemperature protection of the fan through active temperature management
        • IP class IP 54

        Heat exchange with pre-installed valve kit

        • High-efficiency heat exchanger with copper tubes and aluminum fins
        • Suitable for LPHW heating systems
        • Internal and factory-fitted valve kit
        • Optional thermostatic valve or differential pressure independent valve for automatic hydronic balancing
        • Shut-off ball valve in the appliance return
        • Corrugated stainless steel pipes (18 x 1 mm) for connection to the supply lines

        connection and operational safety

        • Device design and component selection optimized for easy installation and operation
        • Reduced overall weight through the use of EPP
        • Connection and pre-assembled corrugated pipes outside the unit
        • External repair switch

        ISO Coarse filter

        • Filters dust from the room air
        • Protection against unintentional tampering and soiling
        • Filter is easy to remove by flipping a latch

        • Itop view
        • IIFront view
        • IIIisometric view

        • 1Flow
        • 2Return
        • 3Repair switch

        We consider the environmental impact of our products throughout their entire life cycle! The result is Environmental Product Declarations (EPDs). The EPDs can be easily submitted to all common building sustainability certification systems, such as DGNB, BREEAM, or LEED, and are available in the download area or directly here via the download button. In addition, the product is registered on the DGNB Navigator building products platform.

        Basic data

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        GWP - Total
        Climate change - total
        kg CO2 eq1.25E+022.95E+006.81E+001.34E+022.80E+002.13E+006.08E-022.88E-021.09E+001.38E+010.00E+001.37E-015.16E+002.92E-01-4.15E+01
        GWP - fossil
        Climate change - fossil
        kg CO2 eq1.24E+022.95E+007.49E+001.34E+022.80E+001.40E+005.82E-022.40E-021.08E+001.37E+010.00E+001.37E-015.16E+002.92E-01-4.12E+01
        GWP - Biogenic
        Climate change - biogenic
        kg CO2 eq0.00E+000.00E+00-7.26E-01-7.26E-010.00E+007.26E-010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        GWP - Luluc
        Climate change - land use and land use change
        kg CO2 eq5.90E-011.04E-034.71E-026.39E-015.34E-043.36E-032.60E-034.78E-031.90E-032.84E-020.00E+004.84E-051.85E-052.45E-05-3.64E-01
        ODP
        Ozone Depletion
        kg CFC-11 eq2.15E-066.15E-081.18E-072.33E-064.95E-081.13E-081.07E-095.16E-103.22E-081.43E-070.00E+002.85E-091.41E-092.24E-09-4.86E-07
        AP
        Acidification
        mol H+ eq2.21E+006.98E-032.84E-022.25E+001.07E-025.11E-022.78E-043.99E-041.21E-022.83E-020.00E+003.23E-047.72E-044.80E-04-3.51E-01
        EP - fresh water
        Eutrophication aquatic freshwater
        kg P eq1.29E-022.38E-058.92E-041.39E-021.23E-052.63E-045.94E-061.59E-061.35E-041.99E-030.00E+001.10E-061.04E-067.91E-07-2.38E-03
        EP - marine
        Eutrophication aquatic marine
        kg P eq3.08E-011.80E-039.36E-033.19E-013.74E-033.09E-037.73E-055.59E-051.40E-035.64E-030.00E+008.28E-053.56E-042.74E-04-3.40E-02
        EP - country
        Eutrophication terrestrial
        mol N eq2.12E+001.99E-029.06E-022.23E+004.10E-024.23E-026.00E-042.54E-041.68E-026.56E-020.00E+009.16E-043.82E-032.07E-03-4.12E-01
        POCP
        Photochemical ozone formation
        kg NMVOC7.41E-011.21E-022.22E-027.76E-011.52E-021.22E-021.83E-041.21E-046.18E-032.10E-020.00E+005.60E-049.75E-048.20E-04-1.53E-01
        ADPE
        Depletion of abiotic resources - minerals and metals
        kg Sb eq2.73E-028.23E-061.35E-052.73E-023.64E-066.74E-044.28E-071.90E-072.66E-042.66E-050.00E+003.82E-072.05E-071.70E-07-2.41E-03
        ADPF
        Abiotic resource depletion - fossil fuels
        MJ1.77E+034.43E+011.05E+021.92E+033.91E+011.58E+019.35E-013.48E-011.46E+012.18E+020.00E+002.05E+006.72E-011.69E+00-5.32E+02
        WDP
        Water use
        m³ depriv.1.74E+002.11E-012.97E+004.92E+001.13E-011.10E+003.30E-021.96E-023.70E-016.08E-010.00E+009.77E-032.61E-021.23E-02-5.36E+00
        GWP-GHG
        Global Warming Potential total excl. biogenic carbon following IPCC AR5 methodology
        kg CO2 eq1.25E+022.96E+007.64E+001.35E+022.80E+001.41E+006.11E-022.89E-021.09E+001.39E+010.00E+001.37E-015.16E+003.16E-01-4.16E+01
        PM
        Particulate Matter emissions
        disease inc.9.69E-062.86E-072.84E-071.03E-051.31E-071.61E-072.61E-091.96E-096.95E-081.20E-070.00E+001.33E-083.68E-091.09E-08-2.90E-06
        IR
        Ionizing radiation, human health
        kBq U-235 eq1.21E+021.95E-022.22E-011.22E+021.02E-024.55E-022.25E-036.36E-044.54E-028.03E-010.00E+009.04E-049.66E-041.52E-03-1.65E+00
        ETP - FW
        Ecotoxicity (fresh water)
        CTUe4.23E+031.05E+013.48E+014.27E+035.62E+001.07E+025.74E-011.76E+003.05E+014.79E+010.00E+004.86E-011.29E+019.14E+01-1.91E+03
        HTP - C
        Human toxicity, cancer effects
        CTUh4.41E-061.88E-081.55E-084.44E-069.20E-091.44E-072.28E-101.02E-102.66E-082.35E-080.00E+008.74E-106.99E-106.42E-10-6.63E-06
        HTP - NC
        Human toxicity, non-cancer effects
        CTUh2.02E-052.84E-087.76E-082.03E-052.74E-085.22E-075.39E-103.51E-108.83E-088.44E-080.00E+001.32E-096.27E-091.13E-08-2.66E-06
        SQP
        Land use related impacts/Soil quality
        -9.73E+024.45E+011.09E+021.13E+031.92E+011.81E+015.98E-014.58E-016.30E+003.62E+010.00E+002.06E+001.95E-013.69E+00-1.19E+02

        Resource use

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        PERE
        Use of renewable primary energy excluding resources used as raw materials
        MJ3.01E+026.82E-012.07E+013.22E+023.43E-012.97E+002.62E-018.56E-021.76E+005.22E+010.00E+003.16E-024.93E-027.11E-02-1.09E+02
        PERM
        Use of renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+003.05E+013.05E+010.00E+00-3.05E+010.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PERT
        Total use of renewable primary energy
        MJ3.01E+026.82E-015.12E+013.52E+023.43E-01-2.75E+012.62E-018.56E-021.76E+005.22E+010.00E+003.16E-024.93E-027.11E-02-1.09E+02
        PENRE
        Use of non-renewable primary energy excluding resources used as raw materials
        MJ1.77E+034.43E+011.05E+021.92E+033.91E+011.58E+019.35E-013.48E-011.46E+012.18E+020.00E+002.05E+006.72E-011.69E+00-5.32E+02
        PENRM
        Use of non-renewable primary energy resources used as raw materials
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        PENRT
        Total use of non-renewable primary energy
        MJ1.77E+034.43E+011.05E+021.92E+033.91E+011.58E+019.35E-013.48E-011.46E+012.18E+020.00E+002.05E+006.72E-011.69E+00-5.32E+02
        SM
        Secondary material
        kg2.58E+000.00E+000.00E+002.58E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RSF
        Renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NRSF
        Non-renewable secondary fuels
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        FW
        Net use of fresh water
        m³3.94E+002.11E-012.94E+007.09E+001.13E-011.12E+003.27E-021.89E-023.74E-015.98E-010.00E+009.77E-032.34E-021.86E-02-5.53E+00

        Waste & Output Flows

        Impact categoryUnitA1A2A3A1-A3A4A5B2B3B4B6C1C2C3C4D
        HWD
        Hazardous waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        NHWD
        Non-hazardous waste disposed
        kg0.00E+000.00E+001.81E+001.81E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        RWD
        Radioactive waste disposed
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        CRU
        Components for reuse
        kg0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+00
        MFR
        Material for recycling
        kg0.00E+000.00E+004.54E+004.54E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.59E+010.00E+000.00E+00
        MER
        Materials for energy recovery
        kg0.00E+000.00E+000.00E+000.00E+000.00E+002.50E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+002.01E+000.00E+000.00E+00
        EE (Electrical)
        Exported energy electrical
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+001.41E+00
        EE (Thermal)
        Exported energy thermal
        MJ0.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+000.00E+003.78E+01