Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 4.06E+01 | 3.31E+00 | 1.35E+00 | -1.62E+01 |
GWP - fossil kg CO2 eq | 4.10E+01 | 2.97E+00 | 1.35E+00 | -1.60E+01 |
GWP - Biogenic kg CO2 eq | -8.85E-01 | 3.21E-01 | 5.40E-04 | -1.23E-02 |
GWP - Luluc kg CO2 eq | 5.24E-01 | 1.62E-02 | 7.01E-05 | -1.33E-01 |
ODP kg CFC-11 eq | 3.50E-06 | 2.09E-07 | 2.79E-08 | -1.13E-06 |
AP mol H+ eq | 3.86E-01 | 2.37E-02 | 5.66E-04 | -1.94E-01 |
EP - fresh water kg P eq | 3.32E-02 | 1.65E-03 | 1.82E-05 | -1.64E-02 |
EP - marine kg P eq | 7.81E-02 | 6.31E-03 | 1.92E-04 | -1.81E-02 |
EP - country mol N eq | 4.70E-01 | 3.33E-02 | 2.02E-03 | -2.07E-01 |
POCP kg NMVOC | 1.39E-01 | 8.00E-03 | 4.84E-04 | -6.12E-02 |
ADPE kg Sb eq | 4.39E-03 | 3.53E-04 | 4.46E-07 | -3.12E-03 |
ADPF MJ | 5.63E+02 | 7.15E+01 | 1.41E+00 | -2.00E+02 |
WDP m³ depriv. | 9.72E+00 | 4.98E-01 | 4.26E-02 | -2.82E+00 |
GWP-GHG kg CO2 eq | 4.03E+01 | 2.95E+00 | 1.35E+00 | -1.56E+01 |
PM disease inc. | 2.93E-06 | 9.15E-08 | 8.70E-09 | -1.16E-06 |
IR kBq U-235 eq | 7.37E+00 | 2.39E+00 | 8.22E-03 | -1.85E+00 |
ETP - FW CTUe | 2.34E+03 | 1.67E+02 | 5.86E+00 | -1.37E+03 |
HTP - C CTUh | 1.84E-07 | 5.20E-09 | 2.16E-10 | -8.42E-08 |
HTP - NC CTUh | 3.54E-06 | 2.21E-07 | 3.08E-09 | -2.11E-06 |
SQP - | 3.00E+02 | 3.50E+01 | 2.00E+00 | -7.82E+01 |
PERE MJ | 1.60E+02 | 1.37E+01 | 4.78E-02 | -4.04E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 1.60E+02 | 1.37E+01 | 4.78E-02 | -4.04E+01 |
PENRE MJ | 5.63E+02 | 7.16E+01 | 1.41E+00 | -2.00E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 5.63E+02 | 7.16E+01 | 1.41E+00 | -2.00E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 2.78E-01 | 3.16E-02 | 1.36E-03 | -9.97E-02 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 1.93E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 5.85E+00 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 4.79E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m