Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 8.03E+01 | 6.54E+00 | 2.67E+00 | -3.20E+01 |
GWP - fossil kg CO2 eq | 8.11E+01 | 5.87E+00 | 2.67E+00 | -3.17E+01 |
GWP - Biogenic kg CO2 eq | -1.75E+00 | 6.36E-01 | 1.07E-03 | -2.42E-02 |
GWP - Luluc kg CO2 eq | 1.04E+00 | 3.20E-02 | 1.39E-04 | -2.62E-01 |
ODP kg CFC-11 eq | 6.91E-06 | 4.13E-07 | 5.51E-08 | -2.22E-06 |
AP mol H+ eq | 7.62E-01 | 4.69E-02 | 1.12E-03 | -3.84E-01 |
EP - fresh water kg P eq | 6.57E-02 | 3.26E-03 | 3.61E-05 | -3.25E-02 |
EP - marine kg P eq | 1.54E-01 | 1.25E-02 | 3.80E-04 | -3.58E-02 |
EP - country mol N eq | 9.29E-01 | 6.59E-02 | 3.99E-03 | -4.09E-01 |
POCP kg NMVOC | 2.75E-01 | 1.58E-02 | 9.58E-04 | -1.21E-01 |
ADPE kg Sb eq | 8.67E-03 | 6.99E-04 | 8.81E-07 | -6.17E-03 |
ADPF MJ | 1.11E+03 | 1.41E+02 | 2.78E+00 | -3.96E+02 |
WDP m³ depriv. | 1.92E+01 | 9.85E-01 | 8.41E-02 | -5.58E+00 |
GWP-GHG kg CO2 eq | 7.97E+01 | 5.83E+00 | 2.67E+00 | -3.08E+01 |
PM disease inc. | 5.79E-06 | 1.81E-07 | 1.72E-08 | -2.29E-06 |
IR kBq U-235 eq | 1.46E+01 | 4.73E+00 | 1.63E-02 | -3.66E+00 |
ETP - FW CTUe | 4.63E+03 | 3.31E+02 | 1.16E+01 | -2.70E+03 |
HTP - C CTUh | 3.64E-07 | 1.03E-08 | 4.26E-10 | -1.67E-07 |
HTP - NC CTUh | 7.00E-06 | 4.37E-07 | 6.09E-09 | -4.17E-06 |
SQP - | 5.93E+02 | 6.92E+01 | 3.95E+00 | -1.55E+02 |
PERE MJ | 3.17E+02 | 2.71E+01 | 9.44E-02 | -7.99E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 3.17E+02 | 2.71E+01 | 9.44E-02 | -7.99E+01 |
PENRE MJ | 1.11E+03 | 1.41E+02 | 2.78E+00 | -3.96E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 1.11E+03 | 1.41E+02 | 2.78E+00 | -3.96E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 5.50E-01 | 6.26E-02 | 2.69E-03 | -1.97E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 3.81E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 1.16E+01 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 9.47E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m
Suitable for: Katherm QK