Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 6.57E+01 | 5.35E+00 | 2.19E+00 | -2.62E+01 |
GWP - fossil kg CO2 eq | 6.63E+01 | 4.81E+00 | 2.19E+00 | -2.59E+01 |
GWP - Biogenic kg CO2 eq | -1.43E+00 | 5.20E-01 | 8.74E-04 | -1.98E-02 |
GWP - Luluc kg CO2 eq | 8.49E-01 | 2.62E-02 | 1.13E-04 | -2.15E-01 |
ODP kg CFC-11 eq | 5.66E-06 | 3.38E-07 | 4.51E-08 | -1.82E-06 |
AP mol H+ eq | 6.24E-01 | 3.84E-02 | 9.16E-04 | -3.14E-01 |
EP - fresh water kg P eq | 5.38E-02 | 2.67E-03 | 2.95E-05 | -2.66E-02 |
EP - marine kg P eq | 1.26E-01 | 1.02E-02 | 3.11E-04 | -2.93E-02 |
EP - country mol N eq | 7.61E-01 | 5.40E-02 | 3.27E-03 | -3.35E-01 |
POCP kg NMVOC | 2.25E-01 | 1.30E-02 | 7.84E-04 | -9.91E-02 |
ADPE kg Sb eq | 7.10E-03 | 5.72E-04 | 7.21E-07 | -5.05E-03 |
ADPF MJ | 9.11E+02 | 1.16E+02 | 2.27E+00 | -3.24E+02 |
WDP m³ depriv. | 1.57E+01 | 8.06E-01 | 6.89E-02 | -4.57E+00 |
GWP-GHG kg CO2 eq | 6.52E+01 | 4.77E+00 | 2.19E+00 | -2.52E+01 |
PM disease inc. | 4.74E-06 | 1.48E-07 | 1.41E-08 | -1.87E-06 |
IR kBq U-235 eq | 1.19E+01 | 3.87E+00 | 1.33E-02 | -3.00E+00 |
ETP - FW CTUe | 3.79E+03 | 2.71E+02 | 9.48E+00 | -2.21E+03 |
HTP - C CTUh | 2.98E-07 | 8.41E-09 | 3.49E-10 | -1.36E-07 |
HTP - NC CTUh | 5.73E-06 | 3.58E-07 | 4.98E-09 | -3.41E-06 |
SQP - | 4.85E+02 | 5.66E+01 | 3.23E+00 | -1.26E+02 |
PERE MJ | 2.59E+02 | 2.21E+01 | 7.73E-02 | -6.54E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 2.59E+02 | 2.21E+01 | 7.73E-02 | -6.54E+01 |
PENRE MJ | 9.11E+02 | 1.16E+02 | 2.27E+00 | -3.24E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 9.11E+02 | 1.16E+02 | 2.27E+00 | -3.24E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 4.50E-01 | 5.12E-02 | 2.20E-03 | -1.61E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 3.12E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 9.47E+00 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 7.75E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m
Suitable for: Katherm QK