Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 5.41E+01 | 4.41E+00 | 1.80E+00 | -2.15E+01 |
GWP - fossil kg CO2 eq | 5.46E+01 | 3.96E+00 | 1.80E+00 | -2.14E+01 |
GWP - Biogenic kg CO2 eq | -1.18E+00 | 4.28E-01 | 7.20E-04 | -1.63E-02 |
GWP - Luluc kg CO2 eq | 6.99E-01 | 2.16E-02 | 9.34E-05 | -1.77E-01 |
ODP kg CFC-11 eq | 4.66E-06 | 2.78E-07 | 3.72E-08 | -1.50E-06 |
AP mol H+ eq | 5.14E-01 | 3.16E-02 | 7.54E-04 | -2.59E-01 |
EP - fresh water kg P eq | 4.43E-02 | 2.20E-03 | 2.43E-05 | -2.19E-02 |
EP - marine kg P eq | 1.04E-01 | 8.41E-03 | 2.56E-04 | -2.41E-02 |
EP - country mol N eq | 6.26E-01 | 4.44E-02 | 2.69E-03 | -2.76E-01 |
POCP kg NMVOC | 1.85E-01 | 1.07E-02 | 6.45E-04 | -8.16E-02 |
ADPE kg Sb eq | 5.84E-03 | 4.71E-04 | 5.94E-07 | -4.16E-03 |
ADPF MJ | 7.50E+02 | 9.53E+01 | 1.87E+00 | -2.67E+02 |
WDP m³ depriv. | 1.30E+01 | 6.64E-01 | 5.67E-02 | -3.76E+00 |
GWP-GHG kg CO2 eq | 5.37E+01 | 3.93E+00 | 1.80E+00 | -2.07E+01 |
PM disease inc. | 3.90E-06 | 1.22E-07 | 1.16E-08 | -1.54E-06 |
IR kBq U-235 eq | 9.81E+00 | 3.19E+00 | 1.10E-02 | -2.47E+00 |
ETP - FW CTUe | 3.12E+03 | 2.23E+02 | 7.80E+00 | -1.82E+03 |
HTP - C CTUh | 2.45E-07 | 6.93E-09 | 2.87E-10 | -1.12E-07 |
HTP - NC CTUh | 4.72E-06 | 2.95E-07 | 4.10E-09 | -2.81E-06 |
SQP - | 3.99E+02 | 4.66E+01 | 2.66E+00 | -1.04E+02 |
PERE MJ | 2.13E+02 | 1.82E+01 | 6.36E-02 | -5.39E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 2.13E+02 | 1.82E+01 | 6.36E-02 | -5.39E+01 |
PENRE MJ | 7.50E+02 | 9.53E+01 | 1.87E+00 | -2.67E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 7.50E+02 | 9.53E+01 | 1.87E+00 | -2.67E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 3.70E-01 | 4.22E-02 | 1.81E-03 | -1.33E-01 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 2.57E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 7.80E+00 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 6.38E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m
Suitable for: Katherm QK