Katherm QK
Overview
• KaControl MC control system for operation via separate touch panel TP 2"
• Room group control of up to ten units via factory-fitted CAN-bus (up to 100 m)
• Demand-led automatic or optional manual fan control
• Freely configurable multifunctional inputs that can be used, for example, to detect temperatures, window contacts, presence detectors, card readers etc.
• Integrated Webserver (Wi-Fi or LAN) for ease of commissioning, parametrisation, trend data analysis etc. on a laptop or mobile device
The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.The long fans installed in Katherm QK units ensure an even air flow through the coil. This also ensures greater comfort and a directed air outlet from the trench.
- For fast connection
- Saves installation time
- Optional valves (accessories)
- For quick and safe electrical connection
- Saves installation time
- For control options: KaControl, -C1 and 230 V electromechanical --00
- Including 230/24 V power unit
- Removable end panel for ease of connection of trenches
- As visual cover and protection against dirt ingress
- A proven combination of copper/aluminium
- Optimised for air flow and heat dissipation
- Painted graphite-grey
Treated supply air can also be fed into the rooms through the Katherm supply air module (Length 400 mm).
Calculate performance data
A | B | C | D | |
---|---|---|---|---|
GWP - Total kg CO2 eq | 3.49E+01 | 2.85E+00 | 1.16E+00 | -1.39E+01 |
GWP - fossil kg CO2 eq | 3.53E+01 | 2.56E+00 | 1.16E+00 | -1.38E+01 |
GWP - Biogenic kg CO2 eq | -7.62E-01 | 2.77E-01 | 4.65E-04 | -1.06E-02 |
GWP - Luluc kg CO2 eq | 4.51E-01 | 1.39E-02 | 6.04E-05 | -1.14E-01 |
ODP kg CFC-11 eq | 3.01E-06 | 1.80E-07 | 2.40E-08 | -9.68E-07 |
AP mol H+ eq | 3.32E-01 | 2.04E-02 | 4.87E-04 | -1.67E-01 |
EP - fresh water kg P eq | 2.86E-02 | 1.42E-03 | 1.57E-05 | -1.41E-02 |
EP - marine kg P eq | 6.72E-02 | 5.43E-03 | 1.66E-04 | -1.56E-02 |
EP - country mol N eq | 4.05E-01 | 2.87E-02 | 1.74E-03 | -1.78E-01 |
POCP kg NMVOC | 1.20E-01 | 6.89E-03 | 4.17E-04 | -5.27E-02 |
ADPE kg Sb eq | 3.77E-03 | 3.04E-04 | 3.83E-07 | -2.68E-03 |
ADPF MJ | 4.84E+02 | 6.16E+01 | 1.21E+00 | -1.72E+02 |
WDP m³ depriv. | 8.37E+00 | 4.29E-01 | 3.66E-02 | -2.43E+00 |
GWP-GHG kg CO2 eq | 3.47E+01 | 2.54E+00 | 1.16E+00 | -1.34E+01 |
PM disease inc. | 2.52E-06 | 7.87E-08 | 7.49E-09 | -9.97E-07 |
IR kBq U-235 eq | 6.34E+00 | 2.06E+00 | 7.07E-03 | -1.59E+00 |
ETP - FW CTUe | 2.01E+03 | 1.44E+02 | 5.04E+00 | -1.18E+03 |
HTP - C CTUh | 1.58E-07 | 4.47E-09 | 1.86E-10 | -7.25E-08 |
HTP - NC CTUh | 3.05E-06 | 1.90E-07 | 2.65E-09 | -1.81E-06 |
SQP - | 2.58E+02 | 3.01E+01 | 1.72E+00 | -6.72E+01 |
PERE MJ | 1.38E+02 | 1.18E+01 | 4.11E-02 | -3.48E+01 |
PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PERT MJ | 1.38E+02 | 1.18E+01 | 4.11E-02 | -3.48E+01 |
PENRE MJ | 4.84E+02 | 6.16E+01 | 1.21E+00 | -1.72E+02 |
PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
PENRT MJ | 4.84E+02 | 6.16E+01 | 1.21E+00 | -1.72E+02 |
SM kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NRSF MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
FW m³ | 2.39E-01 | 2.72E-02 | 1.17E-03 | -8.58E-02 |
HWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
NHWD kg | 1.66E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
RWD kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
MFR kg | 0.00E+00 | 0.00E+00 | 5.04E+00 | 0.00E+00 |
MER kg | 0.00E+00 | 0.00E+00 | 4.12E-01 | 0.00E+00 |
EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Touch Panel TP 2
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl MC
Suitable for: all units with control option KaControl -MC1, -MC2
Surface-mounted housing
Suitable for: Touch Panel TP 2
Surface-mounted housing
Suitable for: Touch Panel TP 2
room temperature sensor
Suitable for: all units with control option KaControl MC
Valve kit
Suitable for: Katherm QK, Katherm QK Trench Technology
Valve body
Suitable for: Katherm NK 182 (trench heights 150 mm and 200 mm), Katherm NK 232/300/380 (all trench heights), Katherm QK, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK
Differential pressure-independent valve kit
Suitable for: DN 15
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Mitred corner
Suitable for: Katherm QK
Installation cover
price per m
Suitable for: Katherm QK