Overview
The newly designed Katherm HK maximises output with minimal noise by optimising the use of space within the floor. Depending on the model, the components are arranged efficiently: with 4-pipe models, the right-hand area of the trench is used for the additional heating mode valve connection, while with 2-pipe models, this area is reduced to a minimum. This flexible design enables the units to be tailor-made to conditions on site and ensures optimum use of every centimetre of the trench system.
The heat exchanger has a connecting internal thread and is secured with an anti-torsion device, which also acts as a splash guard during venting. We offer a wide range of pre-settable Open/Close valve kits and also differential pressure-independent valve kits for smaller or larger water flow rates with corrugated pipes. All models can be factory pre-equipped to save time, in which case only press-fit connections at the copper end piece of the corrugated pipe are required on site.
The ready-wired junction and control box is design for fast and safe electrical wiring. A built-in cable duct ensures clean and safe cabling.
Calculate performance data
| A | B | C | D | |
|---|---|---|---|---|
| GWP - Total kg CO2 eq | 1.11E+02 | 9.78E+00 | 5.01E+00 | -5.76E+01 |
| GWP - fossil kg CO2 eq | 1.14E+02 | 8.73E+00 | 5.01E+00 | -5.70E+01 |
| GWP - Biogenic kg CO2 eq | -3.89E+00 | 1.02E+00 | 1.97E-03 | -2.77E-02 |
| GWP - Luluc kg CO2 eq | 7.98E-01 | 3.37E-02 | 2.45E-04 | -4.14E-01 |
| ODP kg CFC-11 eq | 8.74E-06 | 5.89E-07 | 9.84E-08 | -3.84E-06 |
| AP mol H+ eq | 1.41E+00 | 7.07E-02 | 2.04E-03 | -8.36E-01 |
| EP - fresh water kg P eq | 1.18E-01 | 6.01E-03 | 6.45E-05 | -6.93E-02 |
| EP - marine kg P eq | 1.40E-01 | 8.27E-03 | 6.90E-04 | -7.13E-02 |
| EP - country mol N eq | 1.55E+00 | 9.77E-02 | 7.92E-03 | -8.28E-01 |
| POCP kg NMVOC | 4.47E-01 | 2.45E-02 | 1.74E-03 | -2.40E-01 |
| ADPE kg Sb eq | 1.99E-02 | 2.00E-03 | 1.55E-06 | -1.58E-02 |
| ADPF MJ | 1.52E+03 | 2.16E+02 | 5.10E+00 | -7.03E+02 |
| WDP m³ depriv. | 4.93E+01 | 1.39E+00 | 1.56E-01 | -1.24E+01 |
| GWP-GHG kg CO2 eq | 1.12E+02 | 8.66E+00 | 5.00E+00 | -5.54E+01 |
| PM disease inc. | 7.47E-06 | 2.55E-07 | 3.10E-08 | -4.34E-06 |
| IR kBq U-235 eq | 1.09E+01 | 7.13E+00 | 2.97E-02 | -6.08E+00 |
| ETP - FW CTUe | 8.58E+03 | 4.75E+02 | 2.09E+01 | -6.11E+03 |
| HTP - C CTUh | 5.40E-07 | 1.66E-08 | 6.61E-10 | -3.25E-07 |
| HTP - NC CTUh | 1.31E-05 | 6.89E-07 | 1.06E-08 | -9.55E-06 |
| SQP - | 9.54E+02 | 9.56E+01 | 7.26E+00 | -3.35E+02 |
| PERE MJ | 3.58E+02 | 4.00E+01 | 1.66E-01 | -1.35E+02 |
| PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PERT MJ | 3.58E+02 | 4.00E+01 | 1.66E-01 | -1.35E+02 |
| PENRE MJ | 1.52E+03 | 2.16E+02 | 5.10E+00 | -7.03E+02 |
| PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PENRT MJ | 1.52E+03 | 2.16E+02 | 5.10E+00 | -7.03E+02 |
| SM kg | 7.17E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RSF MJ | 4.87E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NRSF MJ | 3.13E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| FW m³ | 1.03E+00 | 8.71E-02 | 6.42E-03 | -3.90E-01 |
| HWD kg | 3.79E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NHWD kg | 9.46E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RWD kg | 3.15E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| MFR kg | 1.23E-03 | 0.00E+00 | 2.12E+01 | 0.00E+00 |
| MER kg | 5.40E-06 | 0.00E+00 | 1.67E+00 | 0.00E+00 |
| EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
KaController
Suitable for: All units with control configuration KaControl C1
KaController
Suitable for: All units with control configuration KaControl C1
KaController
Suitable for: All units with control configuration KaControl C1
room temperature sensor
Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Suitable for: all units with KaControl -C1 and climate controller art. no. 19600014894*
KaControl Tableau SEL4.0
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101
Serial KNX card
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
Serial CANbus card
Suitable for: All units with control configuration KaControl C1
Serial Modbus card
Required for each device for connection to KaControl panels or on-site Modbus networks.
The communication card slots into the free interface on the PCB.
Suitable for: All units with control configuration KaControl C1
KaControl visualisation
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 100 Units
KaControl visualisation
The KaControl visualisation unit is used to monitor and control individual control zones and secondary air units for 4-pipe heating/cooling, 2-pipe heating or 2-pipe cooling.
The central interface for monitoring Kampmann products provides optimum assistance with technical monitoring.
Suitable for: All units with control configuration KaControl C1 in conjunction with Modbus card Typ3260101, 300 Units
Differential pressure-independent valve kit
Suitable for: Katherm HK, Min. Flow volume 105 l/h, max. Flow volume 1050 l/h, DN 15
Differential pressure-independent valve kit
Suitable for: Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Pre-settable valve kit
Suitable for: Katherm HK, max. Flow volume 920 l/h, DN 15
Pre-settable valve kit
Suitable for: Katherm HK, max. Flow volume 260 l/h, DN 15
valve actuator
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Pre-settable thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
Pre-settable thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Pre-settable thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 260 l/h, DN 15
Pre-setting key
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Pre-setting set
Suitable for: pre-settable valve bodies and valve kits with higher flow from 250 l/h
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Return shut-off valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Differential pressure-independent thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Differential pressure-independent thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Differential pressure-independent thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, Min. Flow volume 105 l/h, max. Flow volume 1050 l/h, DN 15
Pre-settable thermostatic valve
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 920 l/h, DN 15
Filter for air inlet
Suitable for: Katherm HK 290 or Katherm HK 310 P, Length 1340 - 2180 mm
fitting kit for natural condensate drain
Suitable for: Katherm HK
fitting kit for natural condensate drain
Suitable for: Katherm HK
Connection kit for condensation pump
Suitable for: Katherm HK or Katherm HK P, Width 290 mm and 310 mm
Connection kit for condensation pump
Suitable for: Katherm HK or Katherm HK P, Width 290 mm and 310 mm
Installation cover
price per m
Suitable for: Katherm HK 290
Surcharge for aluminium grille version (€/m)
Suitable for: Aluminium, anodised in a colour (brass, bronze, black, bronze finish, painted DB 703), Katherm HK
Surcharge for natural brass grille version (€/m)
Suitable for: Brass, natural, Katherm HK