Trench Technology
Katherm QK
Article no.:
14253101113324
List price
2,946.00 €
plus VAT
Overview
- All factory-fitted components are wired to terminals
- Compact connecting terminal strip
- Convenient/space-saving connection area
- Power supply via on-site power supply components
- Control by Kampmann room thermostats or on-site controls
- Factory-wired
- Saves installation time
- 24 V electromechanical for optimised trench length and height
- KaControl, C1 and electromechanical 230 V, -00 control options with control box with longer connection range
- Fast connection for time- and cost-saving installation on site
- Valves are optionally available as accessories
- Removable end piece to simplify the coupling of trenches
- Serves as visual protection and to protect against dirt
- For optimum heat dissipation
- Consists of a proven combination of copper and aluminium
- Optimised air flow and heat dissipation
- Painted graphite-grey
- With performance-increasing power stages for higher heat outputs
- For even airflow through the coil
- With sound-isolated mounting plates
Calculate performance data
Sound power octave spectrum
The sound power is determined depending on the use according to ISO 3741 (in the echo chamber), according to ISO 3744 (in the low-reflective half-space) or according to ISO 9614 (intensity method).
Oktave Spektrum
EPD data
Item number-specific LCA data based on verified EPD according to EN 15804, which is available for download at The International EPD System. Separate subdivision of life cycle modules available online via button "EPD data sheet". The environmental impacts of module B refer to 1 year of operation. A: Product and construction process stage - B: Use stage - C: End of life stage - D: Benefits and loads beyond the system boundary
| A | B | C | D | |
|---|---|---|---|---|
| GWP - Total kg CO2 eq | 5.99E+01 | 5.88E+00 | 2.40E+00 | -2.87E+01 |
| GWP - fossil kg CO2 eq | 6.10E+01 | 5.28E+00 | 2.40E+00 | -2.85E+01 |
| GWP - Biogenic kg CO2 eq | -1.64E+00 | 5.71E-01 | 9.60E-04 | -2.18E-02 |
| GWP - Luluc kg CO2 eq | 5.68E-01 | 2.88E-02 | 1.25E-04 | -2.36E-01 |
| ODP kg CFC-11 eq | 4.86E-06 | 3.71E-07 | 4.96E-08 | -2.00E-06 |
| AP mol H+ eq | 6.68E-01 | 4.21E-02 | 1.01E-03 | -3.45E-01 |
| EP - fresh water kg P eq | 5.37E-02 | 2.93E-03 | 3.24E-05 | -2.92E-02 |
| EP - marine kg P eq | 1.32E-01 | 1.12E-02 | 3.42E-04 | -3.22E-02 |
| EP - country mol N eq | 7.79E-01 | 5.93E-02 | 3.59E-03 | -3.68E-01 |
| POCP kg NMVOC | 2.27E-01 | 1.42E-02 | 8.61E-04 | -1.09E-01 |
| ADPE kg Sb eq | 7.82E-03 | 6.28E-04 | 7.92E-07 | -5.54E-03 |
| ADPF MJ | 8.30E+02 | 1.27E+02 | 2.50E+00 | -3.56E+02 |
| WDP m³ depriv. | 2.83E+01 | 8.86E-01 | 7.56E-02 | -5.02E+00 |
| GWP-GHG kg CO2 eq | 6.01E+01 | 5.24E+00 | 2.40E+00 | -2.77E+01 |
| PM disease inc. | 3.70E-06 | 1.63E-07 | 1.55E-08 | -2.06E-06 |
| IR kBq U-235 eq | 6.74E+00 | 4.25E+00 | 1.46E-02 | -3.29E+00 |
| ETP - FW CTUe | 3.76E+03 | 2.97E+02 | 1.04E+01 | -2.43E+03 |
| HTP - C CTUh | 2.56E-07 | 9.24E-09 | 3.83E-10 | -1.50E-07 |
| HTP - NC CTUh | 5.33E-06 | 3.93E-07 | 5.47E-09 | -3.75E-06 |
| SQP - | 4.89E+02 | 6.22E+01 | 3.55E+00 | -1.39E+02 |
| PERE MJ | 1.94E+02 | 2.43E+01 | 8.49E-02 | -7.18E+01 |
| PERM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PERT MJ | 1.94E+02 | 2.43E+01 | 8.49E-02 | -7.18E+01 |
| PENRE MJ | 8.30E+02 | 1.27E+02 | 2.50E+00 | -3.56E+02 |
| PENRM MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| PENRT MJ | 8.30E+02 | 1.27E+02 | 2.50E+00 | -3.56E+02 |
| SM kg | 5.15E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RSF MJ | 3.50E-04 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NRSF MJ | 2.25E-02 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| FW m³ | 6.33E-01 | 5.62E-02 | 2.42E-03 | -1.77E-01 |
| HWD kg | 2.72E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| NHWD kg | 5.19E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| RWD kg | 2.26E-03 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| CRU kg | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| MFR kg | 8.80E-04 | 0.00E+00 | 1.04E+01 | 0.00E+00 |
| MER kg | 3.88E-06 | 0.00E+00 | 8.51E-01 | 0.00E+00 |
| EE (Electrical) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
| EE (Thermal) MJ | 0.00E+00 | 0.00E+00 | 0.00E+00 | 0.00E+00 |
Accessories
Control accessories electromechanical 24 V
Clock thermostat
Heating/Cooling, 2- and 4-pipe, continuously variable, with LCD operating menu and integrated timer program, heating/cooling changeover by means of external potential-free contact (low voltage), 24 V Actuator, Open/Closed, 1 W, flush-mounted, Protection class IP 30, Colour similar to RAL 9010 pure white, Type 30456
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Only in conjunction with valves/valve kits!
optional connectible, remote sensor art. no. 196000148921
Suitable for: EC units, electromechanical 24 V/230 V, 5 Katherm HK, Katherm HK 320 E, Katherm QK or Katherm QK nano Trench Technology, 5 PowerKon nano Perimeter Heating
Article no.:
196000030456
List price
427.00 €
plus VAT
power supply unit
for external installation outside the trench heater, 85 - 264 V AC, 24 V DC, 36 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 1 Katherm QK Trench Technology, 3 Katherm QK nano Trench Technology, 3 PowerKon nano Perimeter Heating
Article no.:
196901335152
List price
58.00 €
plus VAT
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 60 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 2 Katherm QK Trench Technology, 5 Katherm QK nano Trench Technology, 6 PowerKon nano Perimeter Heating
Article no.:
196901338401
List price
77.00 €
plus VAT
power supply unit
for external installation outside the trench heater, 86 - 264 V AC, 24 V DC, 47 Hz, 92 W, on DIN rail, Protection class II
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Suitable for: EC units, electromechanical 24 V, 4 Katherm QK Trench Technology, 7 Katherm QK nano Trench Technology, 10 PowerKon nano Perimeter Heating
Article no.:
196901338402
List price
110.00 €
plus VAT
Valve kits
Pre-settable valve kit
Heating, 2-pipe, contains 1 piece pre-settable valve axial form, 1 piece lockshield valve angled form, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm QK Trench Technology, max. Flow volume 260 l/h, DN 15
Suitable for: Katherm QK Trench Technology, max. Flow volume 260 l/h, DN 15
Article no.:
194000145969
List price
64.00 €
plus VAT
Differential pressure-independent valve kit
Heating, 2-pipe, contains 1 piece PICV valve axial form, 1 piece lockshield valve angled form, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm QK Trench Technology, Min. Flow volume 10 l/h, max. Flow volume 170 l/h, DN 15
Suitable for: Katherm QK Trench Technology, Min. Flow volume 10 l/h, max. Flow volume 170 l/h, DN 15
Article no.:
194000347925
List price
100.00 €
plus VAT
Differential pressure-independent valve kit
Heating, 2-pipe, contains 1 piece PICV valve axial form, 1 piece lockshield valve angled form, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm QK Trench Technology, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm QK Trench Technology, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347935
List price
114.00 €
plus VAT
Valve actuators, supplied loose
valve actuator
Drive T, 24 V AC/DC, 2-point, normally closed, 0.5m connecting line-AEH, PVC, VA10N, 1 W, Protection class III, Protection class IP 54 Cable length 0.12 m, supplied separately, made of Polyamide
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Suitable for: All units with electro-mechanical control configuration KaControl C1 in conjunction with 2-way valve or differential pressure-independent valve
Article no.:
196TS0P040500AB
List price
68.00 €
plus VAT
Valves and return shut-off valves
Pre-settable thermostatic valve
2- and 4-pipe, Axial, pre-settable, Connection 1/2 inch, nickel-plated, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, max. Flow volume 260 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, max. Flow volume 260 l/h, DN 15
Article no.:
194000346911
List price
41.00 €
plus VAT
Pre-setting key
Once per project necessary.
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Suitable for: pre-settable valve bodies, valve kits and convector connection kit
Article no.:
194000346915
List price
7.00 €
plus VAT
Return shut-off valve
2- and 4-pipe, angled, Connection 1/2 inch, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Suitable for: Katherm NK, Katherm QK or Katherm HK, max. Flow volume 610 l/h, DN 15
Article no.:
194000145953
List price
22.00 €
plus VAT
Differential pressure-independent thermostatic valve AQ
2- and 4-pipe, Axial shape, differential pressure-dependent, Connection 1/2 inch, nickel-plated, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, Min. Flow volume 10 l/h, max. Flow volume 170 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, Min. Flow volume 10 l/h, max. Flow volume 170 l/h, DN 15
Article no.:
194000347911
List price
78.00 €
plus VAT
Differential pressure independent thermostatic valve AQH
2- and 4-pipe, Axial shape, differential pressure-dependent, Connection 1/2 inch, nickel-plated, Max. operating pressure 10 bar, supplied separately
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Suitable for: Katherm NK, Katherm QK, Katherm HK or Katherm QK nano, Min. Flow volume 35 l/h, max. Flow volume 420 l/h, DN 15
Article no.:
194000347914
List price
92.00 €
plus VAT
Installation covers
Installation cover
to protect trench during installation, factory-fitted, grilles are packed separately
price per m
Suitable for: Katherm QK 215
price per m
Suitable for: Katherm QK 215
Article no.:
194000100922
List price
19.00 €
plus VAT
Surcharge for pressure test
basic price for pressure test
once per project and call-off order, Max. operating pressure 16 bar
Suitable for: Katherm QK Trench Technology
Suitable for: Katherm QK Trench Technology
Article no.:
142990042161
List price
338.00 €
plus VAT
Surcharge for pressure test
for each unit, Max. operating pressure 16 bar
Suitable for: Katherm QK Trench Technology
Suitable for: Katherm QK Trench Technology
Article no.:
142990042160
List price
61.00 €
plus VAT
Downloads
Declarations/Certificates
Certificate ISO 9001, 14001, 50001
PDF
(116 kB)
Digital EPD database Katherm QK
EPD for Katherm QK
PDF
(2.7 MB)
General product information
Products
PDF
(10.3 MB)
Trench Technology – For a comfortable room climate
PDF
(3.1 MB)
Convection and Radiation
PDF
(1.2 MB)
Technical catalogues
Katherm QK, QK nano trench heating
PDF
(5.4 MB)
KaControl MC - Multi Connect
PDF
(2.2 MB)
Manuals
Katherm QK trench heating
PDF
(6.5 MB)
KaControl MC - Multi Connect Climate Control Quick Start Guide
PDF
(2.3 MB)
CAD-Drawings
Katherm QK, trench width 215 mm, trench height 096 mm, 2-pipe, Rostart roll-up grille, control 24V, dimensions [inch]
PDF
(685 kB)
Katherm QK, trench width 215 mm, trench height 096 mm, 2-pipe, Rostart roll-up grille, control 24V, dimensions [mm]
PDF
(682 kB)
Katherm QK, trench width 215 mm, trench height 096 mm, 2-pipe, Rostart roll-up grille, control 24V, dimensions [inch]
DWG
(2.2 MB)
Katherm QK, trench width 215 mm, trench height 096 mm, 2-pipe, Rostart roll-up grille, control 24V, dimensions [mm]
DWG
(2.2 MB)
Installation plans
Katherm QK, electromechanical control 24V
PDF
(685 kB)